Suppr超能文献

透析患者中因表面抗原过量导致乙肝表面抗原检测假阴性:前带现象。

False negative hepatitis B surface antigen detection in dialysis patients due to excess surface antigen: postzone phenomenon.

作者信息

Hefter L G, Hix M A, Stoner M, Cook C B

出版信息

J Clin Pathol. 1980 Oct;33(10):993-4. doi: 10.1136/jcp.33.10.993.

Abstract

Renal dialysis patients are well known to have a high incidence of hepatitis B carrier state. In studying a group of 63 long-term dialysis patients, 10 were found to be positive for hepatitis B surface antigen by radioimmunoassay (RIA). Surprisingly, however, only three of these RIA positive patients were positive by counter immunoelectrophoresis (CIEP). The discrepancy could not be accounted for by the difference in sensitivity of the two methods. The cause for the negative reactions by CIEP in seven patients was found to be the marked excess surface antigen in these sera which produced false negative results by the postzone phenomenon. After dilution all seven sera were positive by CIEP, requiring a dilution up to 1/20 to produce a positive result. Also, all seven sera were positive by the less sensitive Ouchterlony double diffusion.

摘要

众所周知,肾透析患者乙肝携带者状态的发生率很高。在对一组63名长期透析患者的研究中,通过放射免疫测定法(RIA)发现有10名患者乙肝表面抗原呈阳性。然而,令人惊讶的是,这些RIA阳性患者中只有3名通过对流免疫电泳(CIEP)呈阳性。两种方法灵敏度的差异并不能解释这种差异。发现7名患者CIEP呈阴性反应的原因是这些血清中表面抗原显著过量,通过后带现象产生了假阴性结果。稀释后,所有7份血清通过CIEP均呈阳性,需要稀释至1/20才能产生阳性结果。此外,所有7份血清通过灵敏度较低的双向琼脂扩散法也呈阳性。