Shanker S, Daley D A, Sorrell T C
J Clin Pathol. 1981 Apr;34(4):420-3. doi: 10.1136/jcp.34.4.420.
The Phadebact(R) Gonococcus Test, a slide coagglutination test, was compared with the Difco fluorescent antibody test for the identification of Neisseria gonorrhoeae isolated from 18- to 24-hour primary plates. A total of 316 morphologically characteristic, oxidase-positive, Gram-negative diplococci were tested. Altogether 298 isolates were identified definitively as N. gonorrhoeae by a rapid carbohydrate utilisation test; 287 of the 298 isolates of N. gonorrhoeae were identified by the coagglutination test, a sensitivity of 96%. The sensitivity of the fluorescent antibody test was 85% (254 of 298 isolates). False-positive results due to cross-reactions with non-gonococcal Neisseria were uncommon (1 of 18 non-gonococcal isolates in the coagglutination test, a specificity of 94%; 2 of 18 in the fluorescent antibody test, a specificity of 88%). None of the 14 other contaminant organisms seen frequently on primary isolation media gave positive reactions. Interpretation of the coagglutination test proved to be difficult initially. Thirty-two (10%) coagglutination tests had to be repeated; 3 of the 32 (1% of the total isolates tested) remained uninterpretable.
将用于鉴定从18至24小时初代平板分离出的淋病奈瑟菌的Phadebact(R)淋球菌试验(一种玻片凝集试验)与Difco荧光抗体试验进行了比较。共检测了316株形态特征典型、氧化酶阳性的革兰氏阴性双球菌。通过快速碳水化合物利用试验,共有298株菌株被明确鉴定为淋病奈瑟菌;在这298株淋病奈瑟菌分离株中,有287株通过凝集试验得以鉴定,灵敏度为96%。荧光抗体试验的灵敏度为85%(298株分离株中有254株)。与非淋球菌奈瑟菌发生交叉反应导致的假阳性结果并不常见(凝集试验中18株非淋球菌分离株中有1株,特异性为94%;荧光抗体试验中18株中有2株,特异性为88%)。在初代分离培养基上常见的其他14种污染菌均未出现阳性反应。最初,凝集试验的结果解读存在困难。32次(10%)凝集试验需要重复进行;其中3次(占所检测总分离株的1%)仍无法解读。