The physical properties of a jet-nebulizer and their relevance for the histamine provocation test.

作者信息

Sterk P J, Plomp A, Crobach M J, van de Vate J F, Quanjer P H

出版信息

Bull Eur Physiopathol Respir. 1983 Jan-Feb;19(1):27-36.

PMID:6850144
Abstract

We have examined the physical properties of eight specimens of a frequently used jet-nebulizer (Wiesbadener Doppelinhalator). For each nebulizer, under various conditions we measured driving pressure, solution output, solute output, particle concentration and size distribution in the aerosol, and the change of solute concentration in the storage vessel. Using histamine acid phosphate solutions in distilled water, there was considerable variability between the nebulizers in solute output (range about a factor 3). Solute output was strongly related to driving pressure (r2 = 0.89), to solution output (r2 = 0.96) and to particle concentration (r2 = 0.87). The particle size distributions of the eight nebulizers were very similar. The volume median aerodynamic diameter (VMAD) of the stable evaporated particles was on average 0.33 micrograms (geometric standard deviation of 1.78), which implies a VMAD of the primary droplets of about 3.2 micrograms. In fifteen subjects with bronchial hyperreactivity, a twofold increase of histamine output of the nebulizer without a change in particle size resulted on average in a twofold decrease of the histamine concentration that caused a 20 per cent fall (PC20) in FEV1. At constant histamine output the administration of dry particles instead of direct nebulization of (partly) saturated droplets into the mouth increased PC20 by a factor 2. This difference could not be explained by a changed deposition in the hypopharynx. There were large interindividual differences in the response to the altered aerosol characteristics. We conclude that the physical properties of the administered aerosols should be carefully controlled since they influence the biological response to inhaled histamine. The solute output of the investigated jet-nebulizer can satisfactorily be validated by weighing, for which an equation is given. In bronchial provocation testing, administration of dry particles is recommended.

摘要

相似文献

1
The physical properties of a jet-nebulizer and their relevance for the histamine provocation test.
Bull Eur Physiopathol Respir. 1983 Jan-Feb;19(1):27-36.
2
Physical properties of aerosols produced by several jet- and ultrasonic nebulizers.几种喷射式和超声雾化器产生的气溶胶的物理特性。
Bull Eur Physiopathol Respir. 1984 Jan-Feb;20(1):65-72.
3
[Problems of the reproducibility of the inhaled dosage exemplified with the Pari provocation test I apparatus].[以百瑞激发试验I装置为例探讨吸入剂量的可重复性问题]
Pneumologie. 1991 Aug;45 Suppl 2:659-69.
4
Standardization of inhalation provocation tests: influence of nebulizer output, particle size, and method of inhalation.吸入激发试验的标准化:雾化器输出量、颗粒大小及吸入方法的影响
J Allergy Clin Immunol. 1981 Feb;67(2):156-61. doi: 10.1016/0091-6749(81)90012-9.
5
Formulations generated from ethanol-based proliposomes for delivery via medical nebulizers.由基于乙醇的前体脂质体制备的制剂,用于通过医用雾化器给药。
J Pharm Pharmacol. 2006 Jul;58(7):887-94. doi: 10.1211/jpp.58.7.0002.
6
Importance of evaporative water losses during standardized nebulized inhalation provocation tests.标准化雾化吸入激发试验期间蒸发水损失的重要性。
Chest. 1989 Sep;96(3):505-8. doi: 10.1378/chest.96.3.505.
7
Bronchial challenge: a small reservoir for the Wright jet nebulizer.支气管激发试验:用于赖特喷射雾化器的小型储液器。
Bull Eur Physiopathol Respir. 1987 Jan-Feb;23(1):67-71.
8
An aerosol generator system for inhalation delivery of pharmacologic agents.一种用于吸入给药的药物气雾剂发生器系统。
Med Instrum. 1987 Jun;21(3):189-94.
9
Histamine log(dose)-response curves in asthmatics. A comparison between the Wiesbadener Doppelinhalator and the De Vilbiss Model 645 nebulizer.哮喘患者的组胺对数剂量反应曲线。威斯巴登双筒雾化器与德维比斯645型雾化器的比较。
Respiration. 1985;47(4):278-84. doi: 10.1159/000194783.
10
An in vitro study to investigate the use of a breath-actuated, small-volume, pneumatic nebulizer for the delivery of methacholine chloride bronchoprovocation agent.一项体外研究,旨在探究使用一种呼吸驱动的小容量气动雾化器来递送氯化乙酰甲胆碱支气管激发剂。
Respir Care. 2003 Jan;48(1):46-51.

引用本文的文献

1
Propranolol inhalation challenge in relation to histamine response in children with asthma.哮喘患儿中普萘洛尔吸入激发试验与组胺反应的关系
Thorax. 1988 Jun;43(6):451-5. doi: 10.1136/thx.43.6.451.
2
Circadian change in bronchial responsiveness and airflow obstruction in asthmatic children.哮喘儿童支气管反应性和气流阻塞的昼夜变化
Thorax. 1989 Oct;44(10):803-7. doi: 10.1136/thx.44.10.803.