Abstract

The clinical effect of 1.0 mg terbutaline given as a pressurized aerosol with a 750-ml spacer was compared with that of 4.0 mg terbutaline given as a nebulized solution (Pari Inhalier Boy). No differences were found in the parameters measured--forced vital capacity, 1 s forced expiratory volume, forced mid-expiratory flow, and oscillatory resistance. The results indicate that the same clinical response to a given dose of a pressurized aerosol supplied with a 750-ml spacer has the same effect as a fourfold dose via a nebulizer. It is concluded that the more practical 750-ml spacer should be tried when contemplating nebulization therapy.

摘要

将1.0毫克特布他林通过带有750毫升储雾罐的压力定量气雾剂给药,与将4.0毫克特布他林以雾化溶液(帕里吸入宝)给药的临床效果进行比较。在测量参数——用力肺活量、1秒用力呼气量、用力呼气中期流量和振荡阻力方面未发现差异。结果表明,对于给定剂量的通过750毫升储雾罐给药的压力定量气雾剂,其临床反应与通过雾化器给予四倍剂量的效果相同。得出的结论是,在考虑雾化治疗时,应尝试使用更实用的750毫升储雾罐。