Konishi J, Iida Y, Kousaka T, Ikekubo K, Nakagawa T, Torizuka K
Clin Chem. 1982 Jun;28(6):1389-91.
Serum thyroxin was nearly or completely undetectable by radioimmunoassay in an elderly patient with Graves' disease being treated with methimazole. Abnormal binding of thyroxin to antibodies of the IgG variety was shown, the association constant of the complex being 8.0 x 10(8) L/mol and the binding capacity 6.3 nmol/g of IgG. The effect of the antibody on results of radioimmunoassay of free thyroxin was studied with three commercial kits, two of which (Clinical Assays and Damon Diagnostics) gave essentially the same values as did equilibrium dialysis. The third (Amersham International) gave falsely high results because the 125I-labeled thyroxin derivative used in the kit was bound by the autoantibody.
在一名接受甲巯咪唑治疗的老年格雷夫斯病患者中,通过放射免疫测定法几乎检测不到或完全检测不到血清甲状腺素。结果显示甲状腺素与IgG类抗体存在异常结合,复合物的缔合常数为8.0×10⁸L/mol,结合容量为6.3 nmol/g IgG。使用三种商用试剂盒研究了该抗体对游离甲状腺素放射免疫测定结果的影响,其中两种试剂盒(临床检测试剂盒和达蒙诊断试剂盒)给出的结果与平衡透析法基本相同。第三种试剂盒(阿默沙姆国际公司的试剂盒)给出的结果偏高,因为该试剂盒中使用的¹²⁵I标记甲状腺素衍生物被自身抗体结合。