Suppr超能文献

The paper punched disc technique for lead in blood samples with abnormal haemoglobin values.

作者信息

Carter G F

出版信息

Br J Ind Med. 1978 Aug;35(3):235-40. doi: 10.1136/oem.35.3.235.

Abstract

A series of 15 blood samples with haemoglobin levels ranging from 4-6--16-1 g/dl were spotted on to Whatman No. 4 filter paper. Blood samples with low haemoglobin concentrations spread over a greater area of the filter paper than did those with high haemoglobin concentrations. This was further investigated by studying the performance of laboratory-prepared samples, and any effect on the estimation of blood lead value. Blood lead values assayed by the punched disc method on blood samples with low haemoglobin values were unreliable unless the estimated value was adjusted with respect to the area over which the blood had spread.

摘要
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b964/1008412/8dff3c7976d0/brjindmed00075-0045-a.jpg

相似文献

1
The paper punched disc technique for lead in blood samples with abnormal haemoglobin values.
Br J Ind Med. 1978 Aug;35(3):235-40. doi: 10.1136/oem.35.3.235.
3
Rapid, sensitive micro blood lead analysis: a mass screening technique for lead poisoning.
J Anal Toxicol. 1991 Sep-Oct;15(5):237-40. doi: 10.1093/jat/15.5.237.
6
Point of care estimation of haemoglobin in neonates.新生儿血红蛋白的即时检测
Arch Dis Child Fetal Neonatal Ed. 2007 Sep;92(5):F378-80. doi: 10.1136/adc.2006.107771. Epub 2007 Feb 14.