Suppr超能文献

使用Biap狭缝采样器评估手术室空气中的细菌。

Evaluation of airborne operating room bacteria with a Biap slit sampler.

作者信息

Tjade O H, Gabor I

出版信息

J Hyg (Lond). 1980 Feb;84(1):37-40. doi: 10.1017/s0022172400026498.

Abstract

A Biap slit sampler and a Casella Mk 2 slit sampler were studied in an orthopaedic operating theatre. Both showed similar bacterial counts in the range of 74-640 c.f.u. (colony forming units)/m3. During operations, as average count of 220 c.f.u./m3 (range 52-482) was obtained. A close relationship was demonstrated between the number of airborne bacteria and the frequency of traffic through doors.

摘要

在一家骨科手术室对一个比亚普狭缝采样器和一个卡塞拉Mk 2狭缝采样器进行了研究。两者显示出相似的细菌计数,范围在74 - 640 c.f.u.(菌落形成单位)/立方米。在手术过程中,获得的平均计数为220 c.f.u./立方米(范围为52 - 482)。空气中细菌数量与通过门的交通频率之间显示出密切关系。