在一个分区且使用机械通气的病房中金黄色葡萄球菌的鼻腔感染:单一葡萄球菌菌株的地方流行率

Nasal acquisition of Staphylococcus aureus in a subdivided and mechanically ventilated ward: endemic prevalence of a single staphylococcal strain.

作者信息

Lidwell O M, Polakoff S, Davies J, Hewitt J H, Shooter R A, Walker K A, Gaya H, Taylor G W

出版信息

J Hyg (Lond). 1970 Sep;68(3):417-33. doi: 10.1017/s0022172400042327.

Abstract

An investigation was made of nasal acquisition of Staphylococcus aureus and of staphylococcal wound sepsis in a hospital ward divided into two sections and provided with mechanical ventilation, so that there was no transfer of air from one of the sections to the other. Although the strains of S. aureus found in the air, and those colonizing the noses of patients, in the protected section could seldom be related to patients nursed elsewhere in the ward, the mechanical ventilation did not lead to any significant reduction in the degree of contamination of the air or in the rate of nasal acquisition of S. aureus.Even in the protected section, nearly 20% of the strains of S. aureus recovered from the air could not be related to known nasal carriers. Since this proportion was nearly as great as that found in the absence of directed air-flow, it seems probable that these strains were derived either from undetected sources within the section or were dispersed from the clothes of persons who entered it.Nearly one-third of the nasal acquisitions in the ward could not be related to known nasal carriers, but about one-half of these (16%) were probably ;spurious' and half of the remainder (8%) could be related to strains recovered from patients' lesions or drawsheets, leaving no more than 8% unaccounted for. A short investigation in which both drawsheet and perineal samples were examined showed that drawsheet samples did not give a reliable indication of perineal carriage unassociated with nasal carriage.During the period of the investigation, a single strain of S. aureus that was resistant to a wide range of antibiotics established itself in the ward. The most notable character of this strain was the profuse dispersion of it by carriers. As a consequence, staphylococcal wound sepsis increased, with nearly three-quarters of the infections attributable to this strain, and nasal carrier rates increased with length of stay in the ward, over 20% of patients who stayed 5-6 weeks acquiring the strain.

摘要

在一家分为两个区域且配备机械通风设备、两个区域之间无空气流通的医院病房中,对金黄色葡萄球菌的鼻腔感染情况以及葡萄球菌伤口败血症进行了调查。尽管在受保护区域空气中发现的金黄色葡萄球菌菌株以及定植于患者鼻腔的菌株,很少能与病房其他地方护理的患者相关联,但机械通风并未使空气污染程度或金黄色葡萄球菌的鼻腔感染率显著降低。即使在受保护区域,从空气中分离出的近20%的金黄色葡萄球菌菌株也无法与已知的鼻腔携带者相关联。由于这一比例与无定向气流时发现的比例几乎一样大,这些菌株似乎要么源自该区域内未被检测到的来源,要么是由进入该区域的人员衣物传播而来。病房中近三分之一的鼻腔感染无法与已知的鼻腔携带者相关联,但其中约一半(16%)可能是“假阳性”,其余一半(8%)可与从患者伤口或床单上分离出的菌株相关联,剩下的未解释比例不超过8%。一项对床单和会阴样本进行检查的简短调查表明,床单样本并不能可靠地表明与会阴携带情况相关但与鼻腔携带无关的情况。在调查期间,一种对多种抗生素耐药的单一金黄色葡萄球菌菌株在病房中定植。该菌株最显著的特点是携带者大量传播。结果,葡萄球菌伤口败血症增加,近四分之三的感染归因于该菌株,鼻腔携带率随在病房停留时间的延长而增加,在病房停留5 - 6周的患者中,超过20%感染了该菌株。

相似文献

引用本文的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验