[Effects of haemolysis, urea and bilirubin on the precision of digoxin and insulin radioimmunoassays (author's transl)].

作者信息

Dwenger A, Trautschold I

出版信息

J Clin Chem Clin Biochem. 1982 Jan;20(1):29-38.

PMID:7040592
Abstract

The influence of haemolysis, uraemia and hyperbilirubinaemia on the radioimmunoassay for both digoxin and insulin has been investigated for five separation techniques (dextran/charcoal; coated tube; polyethyleneglycol 4000; sodium sulphite; double antibody). Recoveries, and intra- and interassay precision were calculated. It was demonstrated that even in serum samples with a rather high degree of haemolysis (haemoglobin up to 50 g/l)digoxin can be measured by using each of the five separation techniques without any significant interference. Visible haemolysis (haemoglobin above 200 mg/l) leads either to disturbance or to a complete failure of insulin radioimmunoassays with all separation techniques. This effect can be largely neutralized, and precision improved, by using N-ethylmaleimide. With the exception of the coated tube separation technique the intraassay precision has a CV of less than 10%, and the interassay CV is between 10 and 20%. Elevated urea concentrations interfered in the digoxin radioimmunoassay only when the coated tube technique was used. The insulin radioimmunoassay, however was affected by high urea when either the double antibody or the coated tube technique was used. Here the intraassay precision also has a coefficient of variation less than 10%, the interassay CV lying between 10 and 20%. Bilirubin influenced the digoxin test when the sodium sulphite separation was used, and it affected the insulin determinations with polyethyleneglycol 4000 and sodium sulphite. The intra- and interassay precision were however also around 10% and between 10 and 20% respectively. Compared with the interassay precision of 15% CV for digoxin and 13% for insulin for a pool-serum from blood donors, the decrease of interassay precision caused by haemolysis, uraemia and hyperbilirubinaemia was insignificant.

摘要

相似文献

1
[Effects of haemolysis, urea and bilirubin on the precision of digoxin and insulin radioimmunoassays (author's transl)].
J Clin Chem Clin Biochem. 1982 Jan;20(1):29-38.
2
[Comparative study of digoxin determination by E.L.I.S.A. and radioimmunoassay techniques (author's transl)].
Toxicol Eur Res. 1979 May;2(3):149-53.
3
A comparison of automated and manual radioimmunoassays for the estimation of serum digoxin.用于估算血清地高辛的自动化放射免疫分析与手工放射免疫分析的比较。
J Clin Chem Clin Biochem. 1984 Jan;22(1):119-21.
4
[Determination of digoxin in serum. Comparison of radioimmunoassay and a heterogeneous enzyme immunoassay (author's transl)].血清中地高辛的测定。放射免疫分析法与非均相酶免疫分析法的比较(作者译)
J Clin Chem Clin Biochem. 1978 Jun;16(6):335-42.
5
[Determination of serum digoxin. A comparison between RIA and EIA (author's transl)].血清地高辛的测定。放射免疫分析与酶免疫分析的比较(作者译)
Nuklearmedizin. 1979 Dec;18(5):237-40.
6
[A simplified radioimmunoassay for digoxin determination using a 125-j-labelled, solid-phase kit (author's transl)].[使用125I标记的固相试剂盒简化放射免疫分析法测定地高辛(作者译)]
Klin Wochenschr. 1978 May 15;56(10):497-502. doi: 10.1007/BF01492862.
7
Factors affecting the radioimmunoassay of digoxin.
Clin Chem. 1972 Jun;18(6):539-43.
8
Microencapsulated antibodies in radioimmunoassay--I. Determination of digoxin.放射免疫分析中的微囊化抗体——I. 地高辛的测定
Clin Chem. 1979 Jun;25(6):860-2.
9
Evaluation of an immunoturbidimetric assay of serum digoxin without sample pretreatment.无需样品预处理的血清地高辛免疫比浊法评估
Eur J Clin Chem Clin Biochem. 1995 Mar;33(3):171-5.
10
[Haemolysis and turbidity influence on three analysis methods of quantitative determination of total and conjugated bilirubin on ADVIA 1650].[溶血和浊度对ADVIA 1650全自动生化分析仪总胆红素和结合胆红素三种定量测定分析方法的影响]
Ann Biol Clin (Paris). 2008 Mar-Apr;66(2):175-82. doi: 10.1684/abc.2008.0198.