Dorricott N J, Baddeley R M, Keighley M R, Lee J, Oates G D, Alexander-Williams J

出版信息

Ann R Coll Surg Engl. 1982 May;64(3):171-4.

Abstract

The complications and results of rectal anastomoses carried out with the end-to-end anastomosis (EEA) stapling instrument on 50 patients by 5 consultant surgeons are recorded. There was a clinical leakage rate of 6% and a radiological leakage rate of 20% assessed by water-soluble contrast enema. The technique has advantages compared with hand-suture by allowing low anastomoses and preservation of sphincters and is accompanied by an acceptably low leakage rate. Despite the cost of disposable cartridges these advantages make the technique economical because of the avoidance of colostomies and reduction in hospital stay.

摘要

记录了5位顾问外科医生使用端端吻合(EEA)吻合器械对50例患者进行直肠吻合术的并发症及结果。通过水溶性造影剂灌肠评估,临床漏出率为6%,放射学漏出率为20%。与手工缝合相比,该技术具有能进行低位吻合和保留括约肌的优点,且漏出率低至可接受。尽管一次性钉仓成本较高,但由于避免了结肠造口术并缩短了住院时间,这些优点使该技术具有经济性。