Moleman P, Borstrok J J
J Chromatogr. 1982 Feb 12;227(2):391-405. doi: 10.1016/s0378-4347(00)80392-8.
A high-performance liquid chromatographic method with electrochemical detection for the quantitation of total 3-methoxy-4-hydroxyphenylglycol (MHPG) in human urine is described. Existing methods for deconjugation and extraction have been optimized. The present method is simpler than existing methods with a high precision. Urinary MHPG is deconjugated enzymatically and subsequently extracted with ethyl acetate. The organic layer is extracted with acetic acid and a sample of the aqueous layer is injected into a reversed-phase column. In one run 90 samples can be processed. The critical parameters of deconjugation, extraction and chromatography are described. Data for reproducibility and selectivity are presented.
描述了一种采用电化学检测的高效液相色谱法,用于定量测定人尿中总3-甲氧基-4-羟基苯乙二醇(MHPG)。对现有的去结合和提取方法进行了优化。本方法比现有方法更简单,且具有高精度。尿中MHPG经酶促去结合,随后用乙酸乙酯萃取。有机层用乙酸萃取,水层样品注入反相柱。一次运行可处理90个样品。描述了去结合、萃取和色谱的关键参数。给出了重现性和选择性数据。