Suppr超能文献

采用电化学检测改进尿液中3-甲氧基-4-羟基苯乙二醇的液相色谱测定法。

Improved liquid-chromatographic determination of 3-methoxy-4-hydroxyphenylethyleneglycol in urine with electrochemical detection.

作者信息

Shipe J R, Savory J, Wills M R

出版信息

Clin Chem. 1984 Jan;30(1):140-3.

PMID:6690122
Abstract

In this improved method for quantifying 3-methoxy-4-hydroxyphenylethyleneglycol (MHPG) in urine, after a multistep extraction of MHPG and internal standard (iso-MHPG) from 3.0 mL of urine, the compounds are separated on a C18 reversed-phase column and quantified by use of an electro-chemical detector. The isocratic chromatographic separation takes about 16 min. The mobile phase is phosphate buffer/acetonitrile (88/12 by vol), the flow rate 0.7 mL/min. Recycling the mobile phase and automating the sample injection make possible the unattended assay of more than 70 samples per day. The within-run precision of the method is excellent (CV 1.8%) at a mean concentration of 1.1 mg/L.

摘要

在这种改进的尿液中3-甲氧基-4-羟基苯乙二醇(MHPG)定量方法中,从3.0 mL尿液中对MHPG和内标(异-MHPG)进行多步萃取后,这些化合物在C18反相柱上分离,并使用电化学检测器进行定量。等度色谱分离约需16分钟。流动相为磷酸盐缓冲液/乙腈(体积比88/12),流速为0.7 mL/分钟。流动相循环使用以及进样自动化使得每天能够无人值守地检测70多个样品。该方法在平均浓度为1.1 mg/L时,批内精密度极佳(变异系数为1.8%)。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验