Different methods have been used for the determination of serotonin (5HT) in human blood platelets, whole blood and plasma samples, but there have been very few reports on inter-method correlations. We now report the evaluation of fluorometric method using o-phthalaldehyde (OPT), with 3H-5HT as internal standard and GC-MS method using deuterated (d4-) 5-HT as internal standard. Basic extracts (pH 9.5) of sonicated platelet samples, hemolyzed blood or plasma samples are converted to trifluoroacetyl (TFA) or pentafluoropropionyl (PFP) derivatives. An aliquot of this derivatized sample (10%) was used for 3H count for determining the percent recovery, a second aliquot for GC-MS, and the rest for quantitation of OPT fluorescence (Emax360 millimicrons and Fmax 470 millimicrons). In another series, duplicate samples are extracted, one for fluorometry and the second for GS-MS with d4-5-HT as internal standard. Ions m/e 351 and 354 are monitored for the TFA and m/e 451 and 454 for PFP derivatives. The correlation between OPT fluorescence and GS-MS methods was good (0.95) for the platelets, but was poor (0.63) for whole blood and plasma samples. Thin layer chromatography of whole blood and plasma extracts showed multiple spots which yield characteristic fluorescence with OPT spray having same Emax or high background fluorescence. Serotonin levels in platelet samples of normal controls, and patients with different diagnoses of psychiatric disorders are presented.

摘要

已采用不同方法测定人血小板、全血和血浆样本中的血清素(5-羟色胺,5HT),但关于不同方法间相关性的报道极少。我们现报告以邻苯二甲醛(OPT)为荧光测定法,以3H-5HT为内标,以及以氘代(d4-)5-HT为内标的气相色谱-质谱联用(GC-MS)法的评估情况。超声处理后的血小板样本、溶血的血液或血浆样本的碱性提取物(pH 9.5)被转化为三氟乙酰(TFA)或五氟丙酰(PFP)衍生物。取该衍生化样本的一份等分试样(10%)用于3H计数以确定回收率,另一份用于GC-MS,其余用于OPT荧光定量(最大发射波长360纳米,最大荧光强度470纳米)。在另一组实验中,对重复样本进行提取,一份用于荧光测定,另一份以d4-5-HT为内标用于GS-MS。监测TFA衍生物的离子m/e 351和354以及PFP衍生物的离子m/e 451和454。血小板样本中OPT荧光法与GS-MS法之间的相关性良好(0.95),但全血和血浆样本中的相关性较差(0.63)。全血和血浆提取物的薄层色谱显示有多个斑点,用OPT喷雾后产生具有相同最大发射波长的特征荧光或高背景荧光。文中给出了正常对照者以及患有不同精神疾病诊断的患者血小板样本中的血清素水平。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验