Kirkwood T B, Barrowcliffe T W
Br J Haematol. 1978 Oct;40(2):333-8. doi: 10.1111/j.1365-2141.1978.tb03668.x.
Two methods (one-stage and two-stage) are commonly used for the assay of factor VIII clotting activity (VIII:C). We present collected data from seven separate studies of VIII:C assay which show that these methods do not give the same result when comparing concentrates and plasma. On average, two-stage assays detect 20% more VIII:C activity in concentrates as compared to plasmas than do one-stage assays.