Buñag R D, Butterfield J
Hypertension. 1982 Nov-Dec;4(6):898-903. doi: 10.1161/01.hyp.4.6.898.
A new photoelectric sensor capable of detecting tail pulses even in unheated rats was tested for accuracy in indirect measurements of blood pressure. This sensor proved more sensitive than a Doppler ultrasonic flowmeter because it allowed detection not only of tail pulsations without preheating but also of peak oscillations usable for estimating mean arterial pressure. After blood pressures in anesthetized rats were elevated with norepinephrine or lowered with sodium nitroprusside, systolic pressures determined with the photoelectric sensor were almost identical with those recorded concurrently from femoral catheters (r = 0.939). Cuff pressure at peak oscillations in the tail correlated better with femoral mean pressure than with femoral diastolic pressure. However, similar comparisons in awake rats with chronically implanted carotid catheters showed that, although correlation between tail-cuff and carotid systolic pressures remained significant (r = 0.962), the correlation between peak tail oscillations and either mean or diastolic pressure was not. When systolic pressures were measured indirectly once a week for 7 weeks in unheated awake rats, normotensive rats could be easily distinguished from streptozotocin-diabetic and DOCA-salt hypertensive rats.
一种新型光电传感器,即使在未加热的大鼠中也能检测到尾动脉搏动,该传感器用于间接测量血压的准确性已得到测试。这种传感器比多普勒超声流量计更灵敏,因为它不仅能检测到无需预热的尾动脉搏动,还能检测到可用于估算平均动脉压的峰值振荡。在用去甲肾上腺素升高或用硝普钠降低麻醉大鼠的血压后,用光电传感器测定的收缩压与同时从股动脉导管记录的收缩压几乎相同(r = 0.939)。尾动脉峰值振荡时的袖带压力与股动脉平均压的相关性优于与股动脉舒张压的相关性。然而,在清醒且长期植入颈动脉导管的大鼠中进行的类似比较表明,尽管尾袖带压与颈动脉收缩压之间的相关性仍然显著(r = 0.962),但峰值尾动脉振荡与平均压或舒张压之间的相关性并不显著。当在未加热的清醒大鼠中每周间接测量一次收缩压,持续7周时,正常血压大鼠很容易与链脲佐菌素诱导的糖尿病大鼠和去氧皮质酮盐诱导的高血压大鼠区分开来。