Stehlik G, Kainzbauer J, Tausch H, Richter O
J Chromatogr. 1982 Nov 12;232(2):295-303. doi: 10.1016/s0378-4347(00)84169-9.
ExtrelutR extraction and glass capillary gas chromatography were applied to the routine determination of nicotine and its metabolites cotinine, nicotine-1'-N-oxide and cotinine-1-N-oxide in urine and plasma. After extraction of nicotine and cotinine both N-oxides and phendimetrazine-N-oxide (used as internal standard) were reduced to their bases by SO2 on-column and eluted by a mixture of diethyl ether and dichloromethane. The minimum detectable concentrations are 0.03 micrograms/ml for urinary nicotine and cotinine and 0.1 microgram/ml for the N-oxides. In plasma samples the corresponding values are 5 ng/ml and 15 ng/ml, respectively, with sample values as small as 2 ml. The advantage of the direct determination of all four compounds of interest in one sample reduced the amount of plasma required. The straightforward and rapid extraction and reduction procedure as well as the long-term stability of the gas chromatographic separation system make the method suitable for routine application.
采用ExtrelutR萃取法和玻璃毛细管气相色谱法对尿液和血浆中的尼古丁及其代谢物可替宁、尼古丁-1'-N-氧化物和可替宁-1-N-氧化物进行常规测定。萃取尼古丁和可替宁后,两种N-氧化物和苯双甲吗啉-N-氧化物(用作内标)在柱上被SO₂还原为其碱基,并用乙醚和二氯甲烷的混合物洗脱。尿液中尼古丁和可替宁的最低检测浓度为0.03微克/毫升,N-氧化物为0.1微克/毫升。在血浆样品中,相应值分别为5纳克/毫升和15纳克/毫升,样品量低至2毫升。直接测定一个样品中所有四种目标化合物的优点是减少了所需血浆量。直接快速的萃取和还原程序以及气相色谱分离系统的长期稳定性使该方法适用于常规应用。