Griffis L C, Wolff R K, Beethe R L, Hobbs C H, McClellan R O
Fundam Appl Toxicol. 1981 Jan-Feb;1(1):8-12. doi: 10.1093/toxsci/1.1.8.
A multitiered inhalation exposure chamber was evaluated for use in aerosol toxicity studies by determining the uniformity of pulmonary deposition in 144 rats simultaneously exposed to 99mTc-CsCl aerosols. The activity median aerodynamic diameter and geometric standard deviation were 1.7-2.1 micron and 1.8 respectively. In one experiment, lung deposition of 99mTc in male and female rats was 728 and 544 nCi, respectively, after 130 min exposure to an aerosol concentration of 173 nCi/L. Analysis of variance revealed a significant effect of several factors on lung deposition. Animals housed on one side of the chamber had lung burdens 8-11% greater than those on the opposite side. Because an animal's location within the chamber had a slight effect on its lung burden of inhaled aerosol we recommend the rotation of animals among the chamber's six tiers during chronic aerosol toxicity studies. The overall coefficient of variation in lung burden was only 21% which is less than the variability reported in small rodents given a nose-only aerosol exposure.
通过测定144只同时暴露于99mTc - CsCl气溶胶的大鼠肺部沉积的均匀性,对一种多层吸入暴露舱在气溶胶毒性研究中的应用进行了评估。活性中值空气动力学直径和几何标准差分别为1.7 - 2.1微米和1.8。在一项实验中,雄性和雌性大鼠在暴露于浓度为173 nCi/L的气溶胶130分钟后,肺部99mTc的沉积量分别为728和544 nCi。方差分析显示几个因素对肺部沉积有显著影响。饲养在舱一侧的动物肺部负荷比另一侧的动物大8 - 11%。由于动物在舱内的位置对其吸入气溶胶的肺部负荷有轻微影响,我们建议在慢性气溶胶毒性研究期间,在舱的六层之间轮换动物。肺部负荷的总体变异系数仅为21%,低于经鼻单独暴露气溶胶的小型啮齿动物所报告的变异性。