Bellamy R F, Lowensohn H S, Ehrlich W, Baer R W
Am J Physiol. 1980 Jul;239(1):H57-64. doi: 10.1152/ajpheart.1980.239.1.H57.
We studied the effect of transient occlusion of the coronary sinus on the relationship between aortic pressure and circumflex coronary blood flow in open-chest anesthetized dog preparations during artificially prolonged diastoles. The coronary pressure-flow relation was linear, and flow stopped at an arterial pressure (Pf = 0) that always exceeded coronary venous pressure (Pcv). During reactive hyperemia, Pf = 0 was 31 mmHg when Pcv was 5 mmHg and increased to 52 mmHg when the coronary sinus was occluded (Pcv, 38 mmHg). Elevation of Pcv translated the coronary pressure-flow relation to a higher Pf = 0 without altering the slope of the relation. Pf = 0 increased by about two-thirds of the increase in Pcv. We found no evidence that there existed a level of Pcv below which changes in Pcv had no effect on the coronary pressure-flow relation. These data are not compatible with the existence of a vascular waterfall mechanism in the coronary circulation unless it is assumed that Pcv is one of the determinants of Pf = 0.
我们研究了在人工延长舒张期的情况下,冠状动脉窦短暂闭塞对开胸麻醉犬制剂中主动脉压力与左旋冠状动脉血流关系的影响。冠状动脉压力-血流关系呈线性,并且在始终超过冠状静脉压力(Pcv)的动脉压力(Pf = 0)时血流停止。在反应性充血期间,当Pcv为5 mmHg时,Pf = 0为31 mmHg,而当冠状动脉窦闭塞时(Pcv为38 mmHg),Pf = 0增加到52 mmHg。Pcv升高使冠状动脉压力-血流关系转变为更高的Pf = 0,而不改变该关系的斜率。Pf = 0的增加约为Pcv增加量的三分之二。我们没有发现证据表明存在一个Pcv水平,低于该水平时Pcv的变化对冠状动脉压力-血流关系没有影响。除非假设Pcv是Pf = 0的决定因素之一,否则这些数据与冠状动脉循环中存在血管瀑布机制不相符。