Suppr超能文献

Electron-capture gas chromatographic assay for metoclopramide in plasma.

作者信息

Ross-Lee L M, Eadie M J, Bochner F, Hooper W D, Tyrer J H

出版信息

J Chromatogr. 1980 Aug 8;183(2):175-84. doi: 10.1016/s0378-4347(00)81691-6.

Abstract

An original electron-capture gas chromatographic assay has been developed for the quantiation of metoclopramide in human plasma. The method involves derivatization with heptafluorobutyryl imidazole after alkaline extraction, acid backwash, and a further alkaline extraction. Plasma levels of metoclopramide as low as 5 micrograms/l can be measured using 1 ml of plasma, and no interference from related substances or commonly prescribed drugs has been found. The percentage recovery of drug from plasma ranges from 88% to virtually 100%, and the between-run variation in the assay is 4.3%. The assay has been used for the study of metoclopramide pharmacokinetics in man following intravenous single-dose administration. The resultant plasma concentration vs. time curve was biexponential, with a terminal half-life of 5.0 h, and a distribution half-time of 0.3 h.