Staiger C, de Vries J, Walter E
J Clin Chem Clin Biochem. 1980 Nov;18(11):817-9. doi: 10.1515/cclm.1980.18.11.817.
A simple and rapid method for the quantitative determination of antipyrine, using gas-liquid-chromatography with nitrogen detection, is described. Only one extraction step is needed, the recovery is 91.2% and the precision varies between 3.14--1.96%. The lower limit of quantitative assay reached 0.1 mg/l plasma. During routine handling the method was easy, quick and cheap.