Büll U, Kleinhans E, Cyran J, Strauer B E
Herz. 1980 Jun;5(3):133-45.
Employment of a single crystal gamma camera in first pass radionuclide angiography yields essential parameters of left ventricular performance. These are: global ejection fraction, end-diastolic, end-systolic and stroke volumes, regional wall motion and regional ejection fractions. Since the right anterior oblique (30 degree RAO) projection is used, results of this noninvasive method are comparable to findings from invasive contrast ventriculography. A critical evaluation of the comparative results (correlation r = 0.84 to 0.97 in global ejection fraction; r = 0.87 to 0.95 in end-diastolic volume; agreement in segmental wall motion analysis of 72 to 90%) justifies the use of a single crystal gamma camera in first pass radionuclide angiocardiography. At elevated heart rates, e.g. during exercise, the single crystal system yields information of limited value as compared with that of the multiple crystal system. As compared to other methods (e.g. equilibrium methods), short examination times (30 s) of first pass are advantageous. First pass radionuclide angiocardiography may directly precede equilibrium examinations. Within this sequence, it may be used to assess right ventricular function and lung circulation.
在首次通过放射性核素血管造影中使用单晶γ相机可得出左心室功能的基本参数。这些参数包括:整体射血分数、舒张末期容积、收缩末期容积和每搏输出量、局部室壁运动和局部射血分数。由于使用了右前斜位(30度RAO)投影,这种非侵入性方法的结果与侵入性对比心室造影的结果具有可比性。对比较结果的严格评估(整体射血分数的相关性r = 0.84至0.97;舒张末期容积的r = 0.87至0.95;节段性室壁运动分析的一致性为72%至90%)证明了在首次通过放射性核素心血管造影中使用单晶γ相机的合理性。在心率升高时,例如在运动期间,与多晶系统相比,单晶系统产生的信息价值有限。与其他方法(例如平衡法)相比,首次通过的检查时间短(30秒)是有利的。首次通过放射性核素心血管造影可直接先于平衡检查进行。在此序列中,它可用于评估右心室功能和肺循环。