[重复使用的毛细血管透析器在透析中的失血情况]

[Blood loss in dialysis in repeatedly used capillary dialysators].

作者信息

Schmidt U, Senf L, Kleinert P, Thieler H, Marx M

出版信息

Z Gesamte Inn Med. 1980 Nov 1;35(21):797-9.

PMID:7467601
Abstract

The blood losses increase to the twofold to threefold by capillary dialysators C-DAK 4 and C-DAK 5 are about 6.8 ml and 26 ml, respectively, in the first use. In repeated use of the C-DAK 4 the blood losses by the C-DAK 5, however, are so high that it is not to be advised to use them manifold under our conditions of dialysis. By an increase of the reperfusion quantity from 150 to 250 ml of electrolyte solution for one C-DAK 4 blood losses may considerably be reduced. In a parallel switching of two C-DAK 4 each exemplar should be perfused individually.

摘要

首次使用时,毛细血管透析器C - DAK 4和C - DAK 5的失血量分别增加到两倍至三倍,约为6.8毫升和26毫升。然而,在重复使用C - DAK 4时,C - DAK 5的失血量非常高,因此在我们的透析条件下不建议多次使用它们。通过将一个C - DAK 4的再灌注电解质溶液量从150毫升增加到250毫升,失血量可能会大幅减少。在两个C - DAK 4并联切换时,每个样本应单独灌注。