通过连续呼气峰值流量测量来调查职业性哮喘的受试者会伪造他们的结果吗?

Do subjects investigated for occupational asthma through serial peak expiratory flow measurements falsify their results?

作者信息

Malo J L, Trudeau C, Ghezzo H, L'Archevêque J, Cartier A

机构信息

Department of Chest Medicine, Hôpital du Sacré-Coeur, Montreal, Canada.

出版信息

J Allergy Clin Immunol. 1995 Nov;96(5 Pt 1):601-7. doi: 10.1016/s0091-6749(95)70258-x.

Abstract

BACKGROUND AND AIM

Serial assessment of peak expiratory flow (PEF) rates has been advocated as a sensitive and specific means of investigating occupational asthma. The possibility that, for several reasons, subjects do not accurately report their values has been raised. The availability of portable instruments that assess PEF and store timings and values now make it possible to estimate compliance and accuracy of results.

METHODS

Twenty-one subjects consecutively investigated for occupational asthma were asked to assess their PEF every 2 hours during the day, both at work and away from work, with a VMX instrument (Clement Clarke International, Columbus, Ohio) and record the times and values on a sheet of paper. The subjects were not aware that the data were also being stored on a computer chip. The diagnosis was occupational asthma in eight subjects, personal asthma in four subjects, and neither condition in nine subjects.

RESULTS

The mean duration of recording was 36 days (range, 14 to 79 days). At least 6048 values should have been recorded, but only 4839 (80%) were either recorded or stored. Reported values corresponded precisely to stored values in 2533 of 4839 recordings (52%). The timing of the recording was also examined in relation to the time at which the recording was solicited; values recorded within 1 hour of the solicited time were judged as acceptable. Of the total of 3342 recordings stored, 2375 (71%) satisfied this criterion. Compliance was significantly less satisfactory in those referred by the Workers' Compensation Board (n = 11).

CONCLUSION

In this survey of 21 subjects investigated for possible occupational asthma, compliance with PEF recording, as assessed by comparing recorded and stored results and the time at which the recording was solicited, was poor.

摘要

背景与目的

呼气峰值流速(PEF)率的系列评估已被视为调查职业性哮喘的一种敏感且特异的方法。由于多种原因,有人提出受试者可能未准确报告其数值。如今,具备评估PEF并存储时间及数值功能的便携式仪器的出现,使得评估结果的依从性和准确性成为可能。

方法

21名因职业性哮喘而接受连续调查的受试者被要求在白天工作和非工作时段,每隔2小时使用VMX仪器(克莱门特·克拉克国际公司,俄亥俄州哥伦布市)评估其PEF,并在一张纸上记录时间和数值。受试者并不知道数据也存储在计算机芯片上。诊断结果为8名受试者患有职业性哮喘,4名受试者患有个人哮喘,9名受试者两者皆无。

结果

记录的平均时长为36天(范围为14至79天)。本应至少记录6048个数值,但仅有4839个(80%)被记录或存储。在4839次记录中,有2533次(52%)报告的数值与存储的数值完全相符。还检查了记录时间与要求记录的时间的关系;在要求时间的1小时内记录的数值被判定为可接受。在总共存储的3342次记录中,有2375次(71%)符合此标准。由工人赔偿委员会转诊的受试者(n = 11)的依从性明显较差。

结论

在这项对21名可能患有职业性哮喘的受试者的调查中,通过比较记录和存储的结果以及要求记录的时间来评估,PEF记录的依从性较差。