Corbett J M, Dunn M J, Posch A, Görg A
National Heart and Lung Institute, Heart Science Centre, Harefield Hospital, Middlesex, UK.
Electrophoresis. 1994 Aug-Sep;15(8-9):1205-11. doi: 10.1002/elps.11501501182.
An intra- and interlaboratory comparison of positional reproducibility of protein spots in two-dimensional electrophoresis using immobilised pH gradients (IPG) in the first dimension (IPG-DALT) was made. Aliquots of two different samples, human cardiac and barley leaf proteins, were separated in two different laboratories (London and Munich), using 180 mm long IPG gel strips, pH 4-8, for the first dimension and homogeneous SDS-PAGE gels (12% T) for the second dimension. Subsets of 340 (cardiac) and 200 (barley) well-resolved spots distributed across the 2-D gel patterns were selected for computer analysis (PDQUEST) of positional reproducibility. The IPG-dimension was highly reproducible in each laboratory, with a mean standard deviation of about 1 mm for both types of sample. Interlaboratory comparisons revealed identical results for barley with a mean standard deviation along the x-axis of about 1 mm, whereas the cardiac matchset showed slightly more variability (mean standard deviation approximately 1.5 mm). Nevertheless, IPG-DALT provides significantly improved reproducibility of spot positions compared to conventional isoelectric focusing with synthetic carrier ampholytes.
进行了一项关于二维电泳中蛋白质斑点位置重现性的实验室内和实验室间比较,该二维电泳在第一维使用固定化pH梯度(IPG)(IPG-DALT)。将两种不同样品(人心脏蛋白和大麦叶片蛋白)的等分试样在两个不同实验室(伦敦和慕尼黑)进行分离,第一维使用180 mm长的pH 4 - 8的IPG凝胶条,第二维使用均一的SDS-PAGE凝胶(12% T)。从二维凝胶图谱中分布的340个(心脏蛋白)和200个(大麦蛋白)分辨率良好的斑点子集中选择进行位置重现性的计算机分析(PDQUEST)。在每个实验室中,IPG维度的重现性都很高,两种类型的样品平均标准偏差约为1 mm。实验室间比较显示,大麦的结果相同,沿x轴的平均标准偏差约为1 mm,而心脏蛋白匹配集的变异性略大(平均标准偏差约为1.5 mm)。然而,与使用合成载体两性电解质的传统等电聚焦相比,IPG-DALT显著提高了斑点位置的重现性。