Interlaboratory reproducibility of yeast protein patterns analyzed by immobilized pH gradient two-dimensional gel electrophoresis.

作者信息

Blomberg A, Blomberg L, Norbeck J, Fey S J, Larsen P M, Larsen M, Roepstorff P, Degand H, Boutry M, Posch A

机构信息

Department of General and Marine Microbiology, Lundberg Laboratory, University of Göteborg, Sweden.

出版信息

Electrophoresis. 1995 Oct;16(10):1935-45. doi: 10.1002/elps.11501601320.

Abstract

An interlaboratory comparison was conducted on the positional and quantitative reproducibility of yeast proteins resolved by two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) using isoelectric focusing with immobilized pH gradient (pH 4-7) in the first dimension. The basic experimental set-up was as follows: one laboratory prepared and distributed a [35S]methionine-labeled total yeast protein extract (Göteborg, Sweden), another laboratory prepared the IPG strips to be used by all labs in this study (Munich, Germany), the third laboratory (Aarhus, Denmark) circulated the protocols and coordinated the modest attempts to unify them. Samples were run horizontally in the first dimension and vertically in the second. The gels were sent to Göteborg for processing by phosphoimager technology and computerized image analysis (PDQuest), and the 2-D PAGE resolved proteins were located and quantified automatically. A subset of 470 spots was manually matched in all gels out of an average of 1328 resolved proteins. The positional interlaboratory comparison revealed great pattern reproducibility, the correlation coefficient in no case being less than 0.9994. In absolute terms an average deviation of 2.8 mm (x-position) and 1.8 mm (y-position) were obtained for all nine gels (three gels per lab). The interlaboratory comparison of protein quantitation displayed higher variability, and the best correlation coefficient generated was 0.975. An average standard deviation of 34.5% was calculated for protein quantitation including all three labs, a value slightly higher than the intralaboratory variation (range 20-28%). Thus, despite differences in protocols, chemicals and equipment, the immobilized pH gradient technology gave extremely high positional and quantitative reproducibility. This will greatly facilitate the exchange of data and the establishment of multi-user image-based 2-D gel databases.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验