Abstract

The EPC-9 patch-clamp amplifier is a digitally controlled analog device for recording currents in membrane patches and in small cells. It has neither front-panel controls nor internal trim adjustments; instead all gain, range-changing, transient cancellation, calibration and other functions are computer controlled. Novel aspects of the circuit design of this instrument are discussed, with special reference to the issues of allowing computer control of all functions.

摘要

EPC - 9膜片钳放大器是一种用于记录膜片和小细胞中电流的数控模拟设备。它既没有前面板控制装置,也没有内部微调装置;相反,所有增益、量程切换、瞬态消除、校准和其他功能均由计算机控制。本文讨论了该仪器电路设计的新颖之处,特别提及了实现所有功能计算机控制的相关问题。