Suppr超能文献

使用钕:钇铝石榴石激光凝固术在犬前列腺中制造体积性病变:临床治疗概念

Creation of a volume lesion in the dog prostate using neodymium:YAG laser coagulation: concepts for clinical treatment.

作者信息

Perlmutter A P, Lopez M, Vaughan E D

机构信息

Department of Urology, James Buchanan Brady Foundation, New York Hospital-Cornell Medical Center, New York 10021, USA.

出版信息

Lasers Surg Med. 1995;17(1):59-63. doi: 10.1002/lsm.1900170107.

Abstract

BACKGROUND AND OBJECTIVE

The purpose of this study was to determine the geometrical development of a coagulated zone in the canine prostate during free beam side fire Nd:YAG laser coagulation.

STUDY DESIGN/MATERIALS AND METHODS: A series of 10 male dogs underwent endoscopic prostatic Nd:YAG fixed position laser coagulation through a suprapubic cystotomy using a right-angle deflecting delivery catheter (Microvasive, Boston, MA) at times varying from 10 to 120 seconds at 30 watts. In addition, two dogs underwent lasing by pulling the catheter at 1 mm/s in four quadrants. Acute gross and microscopic pathology specimens were prepared and the lesion shape and volume determined.

RESULTS

Analysis of the coagulated volume showed that during the initial 15 seconds of lasing, the zone of coagulation approximates a sphere centered on the urothelium opposite the laser fiber. However, as lasing progressed, the lesion changed from a sphere to an expanding ellipse. This changing geometry can be explained by the absorption and scatter characteristics of the laser and the temperature equilibrium that is established within the prostate.

CONCLUSION

An understanding of this time-dependent geometrical shift from a sphere to an ellipse allows the surgeon to supplement the fixed protocols for lasing at certain positions for given amounts of time. Specific plans can then be established for tissue at the bladder neck, apex, anterior stroma, floor, and irregular prostatic regrowth.

摘要

背景与目的

本研究的目的是确定在犬前列腺进行自由光束侧射钕:钇铝石榴石激光凝固时凝固区的几何形态发展。

研究设计/材料与方法:10只雄性犬通过耻骨上膀胱切开术,使用直角偏转输送导管(Microvasive,波士顿,马萨诸塞州),以30瓦的功率在10至120秒的不同时间进行内镜下前列腺钕:钇铝石榴石固定位置激光凝固。此外,两只犬通过在四个象限以1毫米/秒的速度拉动导管进行激光照射。制备急性大体和显微镜病理标本,并确定病变形状和体积。

结果

对凝固体积的分析表明,在激光照射的最初15秒内,凝固区近似于一个以与激光纤维相对的尿路上皮为中心的球体。然而,随着激光照射的进行,病变从球体变为扩展的椭圆形。这种几何形状的变化可以通过激光的吸收和散射特性以及前列腺内建立的温度平衡来解释。

结论

了解这种从球体到椭圆形的时间依赖性几何形状变化,使外科医生能够补充在特定位置以给定时间进行激光照射的固定方案。然后可以为膀胱颈、尖部、前基质、底部和前列腺不规则再生处的组织制定具体计划。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验