Suppr超能文献

The Tannenbaum stent: a new plastic biliary stent without side holes.

作者信息

Binmoeller K F, Seitz U, Seifert H, Thonke F, Sikka S, Soehendra N

机构信息

Department of Endoscopic Surgery, University Hospital Eppendorf, Hamburg, Germany.

出版信息

Am J Gastroenterol. 1995 Oct;90(10):1764-8.

PMID:7572890
Abstract

OBJECTIVE

Clogging of plastic biliary stents used in malignant biliary obstruction remains a major problem. In vitro studies have shown that side holes, a standard feature of commercially available stents, may contribute to stent clogging. In a pilot study, we designed and prospectively evaluated a new biliary stent without side holes (Tannenbaum stent).

METHODS

Over a 12-month period, 55 consecutive patients (mean age 75 yr) with malignant distal common bile duct obstruction and without papillary or duodenal tumor infiltration underwent endoscopic placement of the Tannenbaum stent for the palliative treatment of jaundice.

RESULTS

Tannenbaum stent insertion was technically successful on the first attempt in all patients and was accompanied by a significant reduction in mean serum bilirubin levels (10.1-1.6 mg%). Fifty-one patients were followed until death (median survival of 130 days); the symptomatic occlusion rate was 16%, the dislocation rate was 8%, and the median stent patency was 64 wk. Aside from stent clogging, there were no complications.

CONCLUSION

The Tannenbaum stent provided effective palliative biliary decompression in all patients. The patency rate was longer than that reported in the literature for conventional plastic stents with side holes and compared favorably with patency rates that have been reported for the metallic expandable biliary stents. The results of this pilot study are encouraging and warrant further studies.