Characterizing beam patterns of miniature (1 to 3 mm diameter) catheter sonographic systems operating at 15 to 50 MHz is difficult and such information is often not provided by manufacturers. For investigators in the field, quantitative information describing catheters and their systems is important to properly understand measurements and images. A practical means of characterizing the system is described that can be assembled in most laboratories and used with existing catheter systems. The ultrasonic beam pattern from an intravascular sonographic transducer is characterized in three dimensions using images generated from a 150 microns diameter spherical target. Experiments are described in which the point spread function or beam pattern is mapped throughout the imaging system field-of-view. Using this approach, the beam pattern and resolutions for a commercial 1.18 mm diameter, 20 MHz intravascular catheter were measured.

摘要

表征直径为1至3毫米的微型导管超声系统在15至50兆赫兹频率下的波束模式是困难的,而且制造商通常不提供此类信息。对于该领域的研究人员而言,描述导管及其系统的定量信息对于正确理解测量结果和图像很重要。本文描述了一种表征该系统的实用方法,该方法可在大多数实验室中组装并与现有的导管系统一起使用。使用由直径150微米的球形目标生成的图像,在三个维度上对血管内超声换能器的超声波束模式进行表征。文中描述了相关实验,其中在整个成像系统视场内绘制点扩散函数或波束模式。采用这种方法,测量了一款商用直径1.18毫米、20兆赫兹的血管内导管的波束模式和分辨率。