Tai M, Fujimaki K, Simizu Y
Research Laboratories, Toyama Chemical Co., Ltd.
Jpn J Antibiot. 1995 May;48(5):621-5.
A high-performance liquid chromatographic procedure was developed for determination of T-3761 in human serum and urine. The method was based on column switching for serum, and direct injection for urine. The peaks were monitored by ultraviolet detection. The calibration curve was linear and quantitative in the concentration range of 0.01-30 micrograms/ml for serum and 0.5-900 micrograms/ml for urine. The intra-assay coefficient of variation was less than 7%. The intra-day and inter-day coefficient of variation were less than 4%.
建立了一种高效液相色谱法用于测定人血清和尿液中的T-3761。该方法对于血清采用柱切换法,对于尿液采用直接进样法。通过紫外检测监测峰。血清校准曲线在0.01 - 30微克/毫升浓度范围内呈线性且可定量,尿液校准曲线在0.5 - 900微克/毫升浓度范围内呈线性且可定量。批内变异系数小于7%。日内和日间变异系数小于4%。