We compared penicillin MICs obtained with three different commercially available broth microdilution panels (MicroScan, Sensititre, and Pasco) with MICs obtained with reference microdilution panels for 20 well-characterized pneumococci with decreased susceptibilities to penicillin (7 resistant and 13 intermediate). All panels were supplemented with 2 to 5% lysed horse blood (LHB) prepared in-house. Additional supplements included fastidious inoculum broth (FIB) for MicroScan panels and commercially prepared LHB (Difco) for Pasco panels. The percentages of penicillin-resistant strains (MIC 2 micrograms/ml) detected by the different methods follow: MicroScan-FIB, 0; MicroScan-LHB 0; Pasco in-house LHB, 71; and Sensititre-LHB, 100. The percentages of intermediate strains (MIC = 0.1 to 1.0 micrograms/ml) detected by the different methods follow: MicroScan-FIB, 31; MicroScan-LHB 23; Pasco in-house LHB, 46; and Sensititre-LHB, 85. Difco LHB supplement failed to support the growth of 86% of the strains in the Pasco panels. Of the commercially available panels evaluated, only Sensititre, supplemented with LHB prepared in-house could reliably detect penicillin-resistant pneumococci.

摘要

我们将使用三种不同的市售肉汤微量稀释板(MicroScan、Sensititre和Pasco)获得的青霉素最低抑菌浓度(MIC)与使用参考微量稀释板获得的20株对青霉素敏感性降低的肺炎链球菌(7株耐药和13株中介)的MIC进行了比较。所有平板均添加了自制的2%至5%溶血马血(LHB)。其他补充剂包括用于MicroScan平板的苛求接种肉汤(FIB)和用于Pasco平板的市售LHB(Difco)。不同方法检测到的青霉素耐药菌株(MIC≥2微克/毫升)的百分比如下:MicroScan - FIB为0;MicroScan - LHB为0;Pasco自制LHB为71%;Sensititre - LHB为100%。不同方法检测到的中介菌株(MIC = 0.1至1.0微克/毫升)的百分比如下:MicroScan - FIB为31%;MicroScan - LHB为23%;Pasco自制LHB为46%;Sensititre - LHB为85%。Difco LHB补充剂未能支持Pasco平板中86%菌株的生长。在所评估的市售平板中,只有补充了自制LHB的Sensititre能够可靠地检测出青霉素耐药肺炎链球菌。

相似文献

3
Testing of Streptococcus pneumoniae for resistance to penicillin.肺炎链球菌对青霉素耐药性的检测。
J Clin Microbiol. 1993 May;31(5):1246-50. doi: 10.1128/jcm.31.5.1246-1250.1993.

引用本文的文献

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验