Suppr超能文献

[Exposure of personnel in interventional radiology].

作者信息

Meier N, Lenzen H, Sudhoff A, Fiebich M, Kötter L

机构信息

Institut für Klinische Radiologie, Westfälische Wilhelms-Universität Münster.

出版信息

Radiologe. 1995 Mar;35(3):152-5.

PMID:7761590
Abstract

The surface dose at five typical positions around the patient couch was measured during transjugular intrahepatic porto-systemic stent shunt (TIPSS) interventions for retrospective calculation of staff dose. Additionally, the surface dose was measured on three members of staff (two radiologists and one technician) by placing thermoluminescence (TL) dosimeters directly on the eyebrows, thyroid, sternum, gonads, hands, knees, and feet. The measured surface dose values and the TL dosimeter measurements are used for estimation of effective dose per examination received by personnel. The effective dose for the radiologists is calculated to 25-35 microSv. The maximum number of examinations allowed per year is calculated on the basis of a given yearly dose limit, by looking at organ dose and effective body dose.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验