Suppr超能文献

使用蔡司四镜接触镜测量视盘

Optic disc measurement with the Zeiss four mirror contact lens.

作者信息

Spencer A F, Vernon S A

机构信息

Academic Unit of Ophthalmology, University Hospital, Nottingham.

出版信息

Br J Ophthalmol. 1994 Oct;78(10):775-80. doi: 10.1136/bjo.78.10.775.

Abstract

A knowledge of the optic disc size may be of value when assessing the glaucoma suspect. The vertical diameter of the optic disc was measured using a Zeiss four mirror gonioscope and a 900 Haag-Streit slit-lamp in one eye of 39 patients, 32 with refractive errors within 3 dioptres of emmetropia. The disc was measured by projecting a slit beam of known height onto the image of the disc. A magnification factor for the contact lens was calculated from first principles and disc height recalculated. These measurements were compared with those obtained by photographic methods using the corrections suggested by Bengtsson and Krakau. In the analysis on the 32 eyes within 3 dioptres of emmetropia the best correlation with clinical measurements was obtained with correction 3 using spectacle refraction and keratometry (r = 0.8614). The contact lens measurement was within plus or minus 0.1 mm of the photographic measurement in 67% of cases and plus or minus 0.2 mm in all cases. This simple method is advocated for the routine assessment of optic disc size.

摘要

在评估疑似青光眼患者时,了解视盘大小可能具有重要价值。使用蔡司四镜前房角镜和900型 Haag-Streit裂隙灯对39例患者的单眼进行视盘垂直径测量,其中32例患者的屈光不正度数在正视眼3屈光度范围内。通过将已知高度的裂隙光束投射到视盘图像上来测量视盘。根据基本原理计算接触镜的放大倍数,并重新计算视盘高度。将这些测量结果与使用Bengtsson和Krakau建议的校正方法通过摄影方法获得的结果进行比较。在对屈光不正度数在正视眼3屈光度范围内的32只眼睛进行的分析中,使用眼镜验光和角膜曲率计的校正3与临床测量结果的相关性最佳(r = 0.8614)。在67%的病例中,接触镜测量值与摄影测量值相差在±0.1 mm以内,在所有病例中相差在±0.2 mm以内。提倡使用这种简单方法对视盘大小进行常规评估。

相似文献

1
Optic disc measurement with the Zeiss four mirror contact lens.使用蔡司四镜接触镜测量视盘
Br J Ophthalmol. 1994 Oct;78(10):775-80. doi: 10.1136/bjo.78.10.775.
9
[Ophthalmoscopic assessment of the size of the optic nerve papilla].
Klin Monbl Augenheilkd. 1997 Nov;211(5):291-5. doi: 10.1055/s-2008-1035137.
10
Ophthalmoscopic measurement of the optic disc.视盘的检眼镜测量
Ophthalmology. 1995 Jul;102(7):1102-6. doi: 10.1016/s0161-6420(95)30905-0.

本文引用的文献

1
Megalopapilla; a new congenital anomaly.巨大乳头;一种新的先天性异常。
Am J Ophthalmol. 1950 Feb;33(2):227-35, illust. doi: 10.1016/0002-9394(50)90841-5.
3
Clinical disc biometry in early glaucoma.早期青光眼的临床椎间盘生物测量法
Ophthalmology. 1993 Jan;100(1):52-6. doi: 10.1016/s0161-6420(13)31713-8.
5
Inter-observer variation in clinical optic disc biometry.
Eye (Lond). 1993;7 ( Pt 3):452-6. doi: 10.1038/eye.1993.91.
10
Reproducibility of photogrammetric optic disc cup measurements.
Invest Ophthalmol Vis Sci. 1985 Jun;26(6):814-7.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验