Engler H D, Shea Y R
Clinical Pathology Department, Warren Grant Magnuson Clinical Center, Bethesda, Maryland 20892.
J Clin Microbiol. 1994 Sep;32(9):2307-8. doi: 10.1128/jcm.32.9.2307-2308.1994.
The PREMIER Cryptococcal Antigen Enzyme Immunoassay (Meridian Diagnostics) did not give discrepant results with rheumatoid factor, syneresis fluid, or serum macroglobulins from systemic lupus erythematosis patients. The Cryptococcal Antigen Latex Agglutination System (Meridian Diagnostics) did cross-react with syneresis fluid but not with the other serum factors tested.
PREMIER新型隐球菌抗原酶免疫测定法(子午线诊断公司)与类风湿因子、凝析液或系统性红斑狼疮患者的血清巨球蛋白检测结果无差异。新型隐球菌抗原乳胶凝集系统(子午线诊断公司)与凝析液有交叉反应,但与其他检测的血清因子无交叉反应。