Heath B J, Done M, Balog O, Ziccone S, Rosewarne F
Department of Anaesthesia, Royal Melbourne Hospital, Parkville, Victoria.
Aust N Z J Obstet Gynaecol. 1994 Aug;34(4):484-6. doi: 10.1111/j.1479-828x.1994.tb01278.x.
United States standards recommend limits to occupational exposure to nitrous oxide. This can be achieved by the scavenging of waste anaesthetic gases, a routine practice in the operating suite, but less common in the delivery suite. In this study, nitrous oxide levels in the delivery room were measured, and scavenged and unscavenged levels were compared. Unacceptable levels of nitrous oxide were found in unscavenged delivery rooms, and in the majority of cases, scavenging reduced nitrous oxide pollution to within recommended limits.
美国标准对职业接触一氧化二氮的限度提出了建议。这可以通过清除废气麻醉气体来实现,这在手术室是常规操作,但在产房不太常见。在本研究中,测量了产房内的一氧化二氮水平,并比较了清除和未清除情况下的水平。在未进行清除的产房内发现了不可接受的一氧化二氮水平,而且在大多数情况下,清除可将一氧化二氮污染降低到建议限度内。