用于测定心搏指数的阻抗心动图。

Impedance cardiography for determination of stroke index.

作者信息

Keim H J, Wallace J M, Thurston H, Case D B, Drayer J I, Laragh J H

出版信息

J Appl Physiol. 1976 Nov;41(5 Pt. 1):797-9. doi: 10.1152/jappl.1976.41.5.797.

DOI:10.1152/jappl.1976.41.5.797
PMID:791918
Abstract

Stroke index obtained by impedance cardiography was compared with values obtained by dye-dilution technique in 17 subjects in 122 determinations made within 2 min of each other. Fifty of these determinations were done after drug administration, postural change, or saline infusion. All values obtained by both methods correlated significantly, but with wide scatter (r=0.49, n = 122, P less than 0.001). The series of determinations within each subject, however, correlated only in one subject significantly; thus any changes of stroke index measured by both techniques were not commensurate. In addition, the impedance stroke index values were significantly lower than the dye-dilution technique, impedance cardiography presently does not determine reliably absolute values of stroke index and is not suitable to evaluate changes of stroke index.

摘要

在17名受试者中,将通过阻抗心动描记术获得的每搏输出量指数与通过染料稀释技术在彼此2分钟内进行的122次测定中获得的值进行比较。其中50次测定是在给药、体位改变或输注生理盐水后进行的。两种方法获得的所有值均显著相关,但离散度较大(r = 0.49,n = 122,P < 0.001)。然而,每个受试者内的一系列测定仅在一名受试者中显著相关;因此,两种技术测量的每搏输出量指数的任何变化都不相符。此外,阻抗每搏输出量指数值显著低于染料稀释技术,目前阻抗心动描记术不能可靠地确定每搏输出量指数的绝对值,也不适合评估每搏输出量指数的变化。

相似文献

1
Impedance cardiography for determination of stroke index.用于测定心搏指数的阻抗心动图。
J Appl Physiol. 1976 Nov;41(5 Pt. 1):797-9. doi: 10.1152/jappl.1976.41.5.797.
2
Measurement of stroke volume with impedance cardiography.用阻抗心动描记法测量心搏量。
Clin Physiol. 1982 Oct;2(5):409-17. doi: 10.1111/j.1475-097x.1982.tb00047.x.
3
Measurement of cardiac stroke volume during cesarean section: a comparison between impedance cardiography and the dye dilution technique.
Acta Anaesthesiol Scand. 1983 Oct;27(5):421-6. doi: 10.1111/j.1399-6576.1983.tb01980.x.
4
Measurement of cardiac stroke volume by impedance cardiography in the last trimester of pregnancy.妊娠晚期通过阻抗心动描记法测量心搏量
Acta Obstet Gynecol Scand. 1983;62(5):473-9. doi: 10.3109/00016348309154222.
5
Comparison of impedance cardiography and dye dilution method for measuring cardiac output.阻抗心动图与染料稀释法测量心输出量的比较。
Heart. 1998 May;79(5):437-41. doi: 10.1136/hrt.79.5.437.
6
Measurement of cardiac output by impedance cardiography in patients with myocardial infarction. Comparative evaluation of impedance and dye dilution methods.
Scand J Clin Lab Invest. 1976 Jan;36(1):29-34. doi: 10.1080/00365517609068015.
7
Measurement of cardiac output by impedance cardiography under various conditions.在各种条件下通过阻抗心动描记法测量心输出量。
Am J Physiol. 1979 Oct;237(4):H491-6. doi: 10.1152/ajpheart.1979.237.4.H491.
8
Cardiac performance measured by impedance cardiography and radionuclide angiography.
Methods Find Exp Clin Pharmacol. 1984 Nov;6(11):717-20.
9
[The noninvasive determination of cardiac output by means of impedance cardiography. Comparative evaluation with a thermal dilution technique (author's transl)].[通过阻抗心动描记法无创测定心输出量。与热稀释技术的比较评估(作者译)]
Basic Res Cardiol. 1976 Sep-Oct;71(5):542-52. doi: 10.1007/BF01909768.
10
Evaluation of impedance cardiography as a non-invasive means of measuring systolic time intervals and cardiac output.评估阻抗心动图作为测量收缩期时间间期和心输出量的非侵入性手段。
Acta Anaesthesiol Scand. 1975;19(3):210-8. doi: 10.1111/j.1399-6576.1975.tb05243.x.

引用本文的文献

1
A comparative evaluation of electrical velocimetry and inert gas rebreathing for the non-invasive assessment of cardiac output.电速度描记法与惰性气体重复呼吸法无创评估心输出量的比较评估。
Clin Res Cardiol. 2011 Oct;100(10):935-43. doi: 10.1007/s00392-011-0329-9. Epub 2011 Jul 1.
2
Non-invasive determination of cardiac output by Doppler echocardiography and electrical bioimpedance.通过多普勒超声心动图和电阻抗法无创测定心输出量。
Br Heart J. 1990 Nov;64(5):347-8. doi: 10.1136/hrt.64.5.347-b.
3
The author reply.作者回复。
Br Heart J. 1989 Jan;61(1):129. doi: 10.1136/hrt.61.1.129.
4
Systolic time intervals: the effect of stroke volume in healthy young men.
Eur J Clin Pharmacol. 1983;24(2):179-83. doi: 10.1007/BF00613814.
5
Contributions to the impedance cardiogram waveform.对阻抗心动图波形的贡献。
Ann Biomed Eng. 1986;14(1):67-80. doi: 10.1007/BF02364649.
6
Automated non-invasive measurement of cardiac output: comparison of electrical bioimpedance and carbon dioxide rebreathing techniques.心输出量的自动无创测量:电阻抗与二氧化碳重呼吸技术的比较
Br Heart J. 1988 Mar;59(3):292-8. doi: 10.1136/hrt.59.3.292.
7
Non-invasive methods of measuring cardiac output.测量心输出量的非侵入性方法。
Intensive Care Med. 1987;13(5):304-9. doi: 10.1007/BF00255784.
8
Transthoracic electrical bioimpedance versus thermodilution technique for cardiac output measurement during mechanical ventilation.机械通气期间经胸电阻抗与热稀释技术用于心输出量测量的比较
Intensive Care Med. 1989;15(4):221-3. doi: 10.1007/BF00271054.
9
An impedance cardiography system: a new design.一种阻抗心动图系统:一种新设计。
Ann Biomed Eng. 1989;17(5):535-56. doi: 10.1007/BF02368072.
10
New signal processing techniques for improved precision of noninvasive impedance cardiography.用于提高无创阻抗心动图精度的新信号处理技术。
Ann Biomed Eng. 1989;17(5):517-34. doi: 10.1007/BF02368071.