[Cell Dyn 3000: technical performance and applications in hematologic pathology].

作者信息

Merle-Béral H

机构信息

Département d'Hématologie, CHU Pitié-Salpêtrière, Paris, France.

出版信息

Nouv Rev Fr Hematol (1978). 1994 Jul;36 Suppl 2:S111-3.

PMID:7971259
Abstract

The Abbott Cell-Dyn (CD) 3000 is an automatic analyser, designed to give cell blood counts (CBC) and white blood differential (WBCD) by 4 angels diffraction analysis. Evaluation was performed by comparison between results obtained by CD and those obtained by Technicon H1 and by microscopic examination. Technical performances as reproducibility, linearity, carryover were quite well acceptable. On normal samples, neutrophils (NE), lymphocytes (LY) and eosinophils (EO) were found to correlate with optical method with coefficient (R) values higher than 0.9. Weaker R coefficients were found for monocytes (MO) and basophils (BA), however it didn't involve clinical consequences. Significant threshold for immature granulocytes (IG) and variant lymphocytes (VL) flags were built. By using those, a false positive rate of 7% was shown. In hematological diseases, no false negative was detected because all samples were flagged. However, no acute lymphoblastic leukemia (ALL) was studied, so the detection of lymphoblast, as known as a real difficulty for analyser, was not yet evaluated. Blasts in acute myeloblastic leukemia (AML) and hairy cells were both noticed by CD. Moreover, for chronic lymphocytic leukemia (CLL), three groups were described, according to the flags released. Knowing its performances and its limits, CD is a good analyser usable in an all round or a hematological laboratory with high number of WBCD per day.

摘要

相似文献

1
[Cell Dyn 3000: technical performance and applications in hematologic pathology].
Nouv Rev Fr Hematol (1978). 1994 Jul;36 Suppl 2:S111-3.
2
Performance evaluation of the haematological analyser Cell-Dyn 3000 (Abbott).
Nouv Rev Fr Hematol (1978). 1994;35(6):535-40.
3
Complete analytical and diagnostic performances of the Abbott Cell Dyn 3500.雅培Cell Dyn 3500的完整分析和诊断性能。
Panminerva Med. 1998 Jun;40(2):116-25.
4
Evaluation of the Abbott CELL-DYN 4000 hematology analyzer.雅培CELL-DYN 4000血液分析仪评估
Am J Clin Pathol. 2000 Apr;113(4):497-505. doi: 10.1309/L7LC-6KKJ-12G2-196W.
5
An evaluation of the differential from the Abbott CD 3500 in a population of patients with haematological abnormalities.
Clin Lab Haematol. 1997 Sep;19(3):191-6.
6
Performance of the Coulter STKS and the Sysmex NE-1500 in a paediatric population.库尔特STKS和希森美康NE - 1500在儿科人群中的性能表现。
Eur J Clin Chem Clin Biochem. 1994 Jul;32(7):563-6.
7
[Analytical evaluation of an automated hematologic analyzer: Cell Dyn 3500].
Minerva Med. 1996 Mar;87(3):123-30.
8
Evaluation of the Beckman Coulter AcT 5 diff AL hematology analyzer in a hospital setting.贝克曼库尔特AcT 5 diff AL血液分析仪在医院环境中的评估
Lab Hematol. 2003;9(3):167-74.
9
[Evaluation of a new automatic hematological system: the Advia 70 (Bayer-Diagnostics)].[一种新型自动血液学系统的评估:Advia 70(拜耳诊断公司)]
Ann Biol Clin (Paris). 2002 Sep-Oct;60(5):541-8.
10
Automated five-part white blood cell differential counts. Efficiency of software-generated white blood cell suspect flags of the hematology analyzers Sysmex SE-9000, Sysmex NE-8000, and Coulter STKS.自动化五分类白细胞计数。血液分析仪Sysmex SE - 9000、Sysmex NE - 8000和库尔特STKS软件生成的白细胞可疑标记的效率。
Arch Pathol Lab Med. 1997 Jun;121(6):573-7.