• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Performance evaluation of the haematological analyser Cell-Dyn 3000 (Abbott).

作者信息

Aubert-Letrillart B, Binet J L, Baudet S, Azgui Z, Merle-Béral H

机构信息

Laboratoire Central d'Hématologie, Hôpital Pitié-Salpêtrère, Paris, France.

出版信息

Nouv Rev Fr Hematol (1978). 1994;35(6):535-40.

PMID:8152899
Abstract

The Abbott Cell Dyn (CD) 3000 is an automatic analyser, designed to give a complete blood count (CBC) and white blood cell differential (WBCD) by 4 angle diffraction analysis. This instrument was evaluated by comparison of results obtained with those obtained from a Technicon H1 analyser and by microscopic examination. Technical performances with regard to reproducibility, linearity and carryover was acceptable and in normal samples there was close correlation with the optical method (R > 0.9) for neutrophils (NE), lymphocytes (LY) and eosinophils (EO). Correlation for monocytes (MO) and basophils (BA) was poorer but without clinical consequences. Significant thresholds for immature granulocyte (IG) and variant lymphocyte (VL) flags were determined and using these thresholds the false positive rate was reduced to 7%. In haematological diseases, no false negatives were observed as all samples were flagged. However, since no case of acute lymphoblastic leukaemia (ALL) was studied, the detection of lymphoblasts which is known to present difficulties for analysers remains to be evaluated. Blasts in acute myeloblastic leukaemia (AML) and hairy cells were recognised, while in chronic lymphocytic leukaemia (CLL) it was possible to define 3 groups according to the flags released. The CD appears to be a satisfactory analyser for use in general or haematological laboratories performing a large number of WBCD per day.

摘要

相似文献

1
Performance evaluation of the haematological analyser Cell-Dyn 3000 (Abbott).
Nouv Rev Fr Hematol (1978). 1994;35(6):535-40.
2
[Cell Dyn 3000: technical performance and applications in hematologic pathology].
Nouv Rev Fr Hematol (1978). 1994 Jul;36 Suppl 2:S111-3.
3
Complete analytical and diagnostic performances of the Abbott Cell Dyn 3500.雅培Cell Dyn 3500的完整分析和诊断性能。
Panminerva Med. 1998 Jun;40(2):116-25.
4
An evaluation of the differential from the Abbott CD 3500 in a population of patients with haematological abnormalities.
Clin Lab Haematol. 1997 Sep;19(3):191-6.
5
Evaluation of the Beckman Coulter AcT 5 diff AL hematology analyzer in a hospital setting.贝克曼库尔特AcT 5 diff AL血液分析仪在医院环境中的评估
Lab Hematol. 2003;9(3):167-74.
6
Evaluation of the Abbott CELL-DYN 4000 hematology analyzer.雅培CELL-DYN 4000血液分析仪评估
Am J Clin Pathol. 2000 Apr;113(4):497-505. doi: 10.1309/L7LC-6KKJ-12G2-196W.
7
Performance evaluation of the Abbott Cell-Dyn 1800 automated hematology analyzer.
Lab Hematol. 2003;9(3):143-52.
8
[Evaluation of a new automatic hematological system: the Advia 70 (Bayer-Diagnostics)].[一种新型自动血液学系统的评估:Advia 70(拜耳诊断公司)]
Ann Biol Clin (Paris). 2002 Sep-Oct;60(5):541-8.
9
[Automated blood cell measurements: a comparison between the Bayer H2 and the Abbott Cell-Dyn 3500].[自动血细胞测量:拜耳H2与雅培Cell-Dyn 3500的比较]
Minerva Med. 1996 Jan-Feb;87(1-2):57-64.
10
Performance of the Coulter STKS and the Sysmex NE-1500 in a paediatric population.库尔特STKS和希森美康NE - 1500在儿科人群中的性能表现。
Eur J Clin Chem Clin Biochem. 1994 Jul;32(7):563-6.