Steffen R, Nolte L P, Pingel T H
Orthopädische Universitätsklinik, St. Josef-Hospital, Ruhr-Universität Bochum.
Rehabilitation (Stuttg). 1994 Aug;33(3):164-70.
In the present study, a biomechanical in-vitro experimental design for assessing lumbar instability following discectomy had been complemented by computer simulation of the muscular influence. The most impressive changes of the instability parameters chosen, i.e., mobility (flexibility) and neutral zone, occurred in respect of the study movement directions Ty, Tz and Mx (lumbar disc height, anterior/posterior dislocation, and flexion/extension). The influence of the multifidus muscle had enabled the flexion/extension neutral zone changes to be offset. Flexibility (+/- Rx) was found to have been influenced to a minor degree.
在本研究中,一种用于评估椎间盘切除术后腰椎不稳的生物力学体外实验设计,已通过肌肉影响的计算机模拟得到补充。所选不稳定参数(即活动度(柔韧性)和中性区)最显著的变化,发生在研究运动方向Ty、Tz和Mx(腰椎间盘高度、前后移位以及屈伸)方面。多裂肌的影响使得屈伸中性区的变化得以抵消。发现柔韧性(+/- Rx)受到的影响较小。