Suppr超能文献

在各种热环境下模拟工作期间穿着密封防护服时的体温调节反应。

Thermoregulatory response to wearing encapsulated protective clothing during simulated work in various thermal environments.

作者信息

Payne W R, Portier B, Fairweather I, Zhou S, Snow R

机构信息

School of Human Movement and Sport Sciences, Ballarat University College, Victoria, Australia.

出版信息

Am Ind Hyg Assoc J. 1994 Jun;55(6):529-36. doi: 10.1080/15428119491018808.

Abstract

This investigation assessed the thermoregulatory impact of performing simulated tasks normally encountered during chemical accident clean-up while wearing chemical protection clothing under various representative thermal loads. A Drager 500 (D) suit was worn with a self-contained breathing apparatus (SCBA) external to the suit, while both a Trelleborg Trellchem Super Extra (T) and a James North MZ500 (J) suit required the SCBA to be worn inside the suit. The D suit was unventilated, while the T and S suits were ventilated with the subject's exhaled air. The T suit also was ventilated via a 2 L/min flow of air from the SCBA. Subjects were six firefighters. Each simulation lasted for 30 minutes and involved tasks such as drum rolling, drum carrying, walking, and hose dragging. The trials were conducted at 11.3, 17.1, and 23.8 degrees C WBGT. The overall mean peak heart rate was 128.1 +/- 2.80 breaths/min and was elicited while performing lifting tasks. Nonsignificant differences (p > 0.05) were observed for both the average heart rate and sweat rate. Mean skin temperature, mean body temperature, and temperature within the suit cavity were significantly higher when wearing the D suit compared to wearing T or J suits; differences between the T and J suits were nonsignificant. Suit type did not significantly affect rectal temperature, which also failed to exceed the American Council of Governmental Industrial Hygienists' (ACGIH) standard of 38.0 degrees C.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

本研究评估了在各种具有代表性的热负荷条件下,穿着化学防护服进行化学事故清理中常见模拟任务时的体温调节影响。Drager 500(D)防护服搭配独立于防护服外的自给式呼吸器(SCBA),而特瑞堡Trellchem Super Extra(T)防护服和James North MZ500(J)防护服则要求将SCBA穿戴在防护服内。D防护服不通风,而T和J防护服通过受试者呼出的空气进行通风。T防护服还通过来自SCBA的2升/分钟的气流进行通风。受试者为六名消防员。每次模拟持续30分钟,包括诸如滚动桶、搬运桶、行走和拖拽软管等任务。试验在湿球黑球温度(WBGT)为11.3、17.1和23.8摄氏度的条件下进行。总体平均峰值心率为128.1±2.80次/分钟,在进行举重任务时出现。平均心率和出汗率均无显著差异(p>0.05)。与穿着T或J防护服相比,穿着D防护服时平均皮肤温度、平均体温和防护服腔内温度显著更高;T和J防护服之间的差异不显著。防护服类型对直肠温度没有显著影响,直肠温度也未超过美国政府工业卫生学家会议(ACGIH)规定的38.0摄氏度标准。(摘要截选至250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验