Force delivery properties of colored elastomeric modules.

作者信息

Baty D L, Volz J E, von Fraunhofer J A

机构信息

US Army Advanced Education Program-Orthodontics, Ft. Knox, Ky.

出版信息

Am J Orthod Dentofacial Orthop. 1994 Jul;106(1):40-6. doi: 10.1016/S0889-5406(94)70019-2.

Abstract

Elastomeric chains have been used by clinicians for some time to accomplish various treatment objectives. Recently, a number of manufacturers have added colored elastomeric chains to their inventories. The present study was designed to investigate the force delivery capabilities and dimensional stability of these new colored chains. Four different colors of short filament configuration produced by three manufacturers were examined. The force delivery capabilities of each chain were tested at 0 hours and, after storage at 37 degrees C in air, distilled water, and artificial saliva, at 1 hour, 4 hours, 24 hours, 1 week, 2 weeks, and 3 weeks. A universal testing machine was used to determine the amount of distraction necessary to generate 150 and 300 gf. Dimensional measurements were assessed initially and, after exposure to a simulated oral environment, at 1, 2, and 3 weeks. The data from the force delivery portion of the study were analyzed with a 4-factor factorial analysis of variance. The data compiled from the dimensional stability portion were subjected to a 3-factor factorial analysis of variance. Follow-up Bonferroni simultaneous t tests (family-wise a priori alpha p < 0.05) was used to determine statistical significance of the differences among sets of means. All colored elastomeric chains in the study appeared capable of initially generating force levels compatible with tooth movement. After 24 hours of storage in liquid, the amount of distraction needed to produce 150 and 300 gf substantially increased. The amount of increased need varied among manufacturers. All chains showed an increase in dimensional measurements after 1 week, with little change thereafter.

摘要

一段时间以来,临床医生一直使用弹性链来实现各种治疗目标。最近,许多制造商已将彩色弹性链添加到其产品库存中。本研究旨在调查这些新型彩色链的力传递能力和尺寸稳定性。对由三个制造商生产的四种不同颜色的短丝结构进行了检查。在0小时时测试每条链的力传递能力,并在37摄氏度的空气中、蒸馏水中和人工唾液中储存后,分别在1小时、4小时、24小时、1周、2周和3周时进行测试。使用万能试验机确定产生150和300克力所需的牵张力。最初评估尺寸测量,在暴露于模拟口腔环境后,分别在1周、2周和3周时进行评估。对研究中力传递部分的数据进行四因素方差分析。对尺寸稳定性部分汇编的数据进行三因素方差分析。后续使用Bonferroni同时t检验(家族性先验α p < 0.05)来确定均值集之间差异的统计学显著性。研究中的所有彩色弹性链最初似乎都能够产生与牙齿移动相适应的力水平。在液体中储存24小时后,产生150和300克力所需的牵张力大幅增加。所需增加量因制造商而异。所有链在1周后尺寸测量均增加,此后变化不大。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验