Suppr超能文献

不锈钢筋膜吻合钉与聚丙烯缝合材料用于犬白线闭合的比较。

Comparison of stainless steel fascial staples and polypropylene suture material for closure of the linea alba in dogs.

作者信息

Kirpensteijn J, Fingland R B, Boyer J E, Kennedy G A, Klemm R D, Debowes R M

机构信息

Department of Clinical Sciences, Kansas State University, Manhattan.

出版信息

Vet Surg. 1993 Nov-Dec;22(6):464-72. doi: 10.1111/j.1532-950x.1993.tb00423.x.

Abstract

Five centimeter segments of the linea alba in mature, female, mixed breed dogs were incised and then approximated with either stainless steel fascial staples or size 0 polypropylene suture material. Breaking strength of the linea alba closures was determined at 0 (Phase I, 18 dogs) and at 7, 14, and 31 days (Phase II, 18 dogs). Histology and videointeractive planar morphometry were used to evaluate healing of the linea alba. Breaking strength and histologic and morphometric variables were analyzed statistically using analysis of variance in a split plot design. In a clinical trial, 20 cm linea alba incisions were approximated with stainless steel fascial staples after elective ovariohysterectomy in mature, female, mixed breed dogs (Phase III, eight dogs). The dogs were evaluated at 1, 2, 7, 14, 31, 90, and 180 days. Linea alba incisions approximated with polypropylene suture material were significantly stronger than linea alba incisions approximated with stainless steel fascial staples on day 0. There was no significant difference between breaking strength values, histologic, and morphometric appearance of linea alba incisions closed with stainless steel fascial staples or polypropylene suture material when compared 7, 14, and 31 days after surgery. All of the dogs in the clinical trial appeared to be normal at all evaluation times. Approximation of linea alba incisions with stainless steel fascial staples compares favorably to closure with a simple continuous pattern of polypropylene suture material with regard to breaking strength, clinical, histologic, and morphometric appearance.

摘要

在成年雌性杂种犬身上,切开5厘米长的白线节段,然后分别用不锈钢筋膜钉或0号聚丙烯缝合材料进行对合。在术后0天(第一阶段,18只犬)以及7天、14天和31天(第二阶段,18只犬)测定白线闭合处的抗断裂强度。采用组织学和视频交互式平面形态测量法评估白线的愈合情况。使用裂区设计的方差分析对抗断裂强度以及组织学和形态测量变量进行统计学分析。在一项临床试验中,对成年雌性杂种犬进行择期卵巢子宫切除术后,用不锈钢筋膜钉对20厘米长的白线切口进行对合(第三阶段,8只犬)。在术后1天、2天、7天、14天、31天、90天和180天对犬进行评估。在术后0天时,用聚丙烯缝合材料对合的白线切口明显比用不锈钢筋膜钉对合的白线切口更牢固。在术后7天、14天和31天进行比较时,用不锈钢筋膜钉或聚丙烯缝合材料闭合的白线切口,其抗断裂强度值、组织学和形态测量外观之间没有显著差异。在所有评估时间,临床试验中的所有犬看起来均正常。就抗断裂强度、临床、组织学和形态测量外观而言,用不锈钢筋膜钉对合白线切口与用简单连续缝合方式的聚丙烯缝合材料闭合切口相比效果良好。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验