Suppr超能文献

[针对非稳态增量测试程序的正常受试者的运动肺量计研究]

[Ergospirometric studies of normal probands for an unsteady-state increment test program].

作者信息

Pothoff G, Winter U, Wassermann K, Jäkel D, Steinbach M

机构信息

Klinik III für Innere Medizin, Universität zu Köln.

出版信息

Z Kardiol. 1994 Feb;83(2):116-23.

PMID:8165841
Abstract

One-hundred-sixteen healthy subjects (60 female and 56 male) with normal height (L) and weight (w) were selected to provide an even distribution of age (A, 20-70 years). All underwent an unsteady state cycle ergometer test with work increments of 20 watts each minute to exhaustion. A commercially available exercise testing system (EOS SPRINT, Jäger Corp., FRG) with gas analysis from a mixing chamber was used to study oxygen uptake (VO2), carbon dioxide output (VCO2), heart rate (HR), tidal volume (VT), breathing frequency (BR) and arterial oxygen tension (PO2) with special regard to the ventilatory anaerobic threshold (VAT) and maximum power output. For all parameters multiple regression equations were determined. Furthermore, heart rate reserve (HR-reserve), breathing reserve (VE-reserve), O2-pulse (VO2/HR), the dead space/tidal volume ratio (VD/VT) and the alveolar-arterial PO2-difference (AaDO2) were calculated. Day-to-day reproducibility was proven in 21 subjects. VO2max in females was 1584 +/- 300 ml/min (VO2max = -17 A + 10 L + 10 G + 58, r = 0.75, p < 0.0001), VO2AT 957 +/- 159 ml/min (VO2AT = 0.35 VO2max + 0.40 l/min, r = 0.77, p < 0.0001). The ratio VO2AT/VO2max was 50 +/- 7%. In male, VO2max was 2452 +/- 529 ml/min (VO2max = -23 A + 23 L + 9.5 G - 1395, r = 0.78, p < 0.0001), VO2AT 1209 +/- 213 ml/min (VO2AT = 0.29 VO2max + 0.51 l/min, r = 0.71, p < 0.0001), and VO2AT/VO2max 62 +/- 9%.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

选取116名身高(L)和体重(w)正常的健康受试者(60名女性和56名男性),以确保年龄(A,20 - 70岁)分布均匀。所有受试者均进行非稳态周期测力计测试,每分钟工作负荷递增20瓦直至力竭。使用一种市售的带有混合室气体分析功能的运动测试系统(EOS SPRINT,耶格公司,联邦德国)来研究摄氧量(VO₂)、二氧化碳排出量(VCO₂)、心率(HR)、潮气量(VT)、呼吸频率(BR)和动脉血氧分压(PO₂),特别关注通气无氧阈(VAT)和最大功率输出。针对所有参数确定了多元回归方程。此外,还计算了心率储备(HR - reserve)、通气储备(VE - reserve)、氧脉搏(VO₂/HR)、死腔/潮气量比值(VD/VT)和肺泡 - 动脉血氧分压差(AaDO₂)。在21名受试者中证明了每日重复性。女性的最大摄氧量(VO₂max)为1584±300毫升/分钟(VO₂max = -17A + 10L + 10G + 58,r = 0.75,p < 0.0001),无氧阈摄氧量(VO₂AT)为957±159毫升/分钟(VO₂AT = 0.35VO₂max + 0.40升/分钟,r = 0.77,p < 0.0001)。VO₂AT/VO₂max比值为50±7%。男性的VO₂max为2452±529毫升/分钟(VO₂max = -23A + 23L + 9.5G - 1395,r = 0.78,p < 0.0001),VO₂AT为1209±213毫升/分钟(VO₂AT = 0.29VO₂max + 0.51升/分钟,r = 0.71,p < 0.0001),VO₂AT/VO₂max为62±9%。(摘要截断于250字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验