PURPOSE

The accuracy of fluoroscopy-guided hip aspiration in the diagnosis of infection in hip prostheses was evaluated.

MATERIALS AND METHODS

Results from 147 preoperative aspiration cultures were compared with results of operative cultures. The relative costs of aspiration and nuclear medicine studies were also compared.

RESULTS

With the operative culture results as the standard, sensitivity of hip aspiration was 92.8% and specificity was 91.7%. The negative and positive predictive values were 99.2% and 54.2%, respectively. Aspiration arthrography costs approximately 20% as much as complementary technetium sulfur colloid-indium-111 granulocyte scans, the most accurate nuclear medicine study used to evaluate potentially infected hip prostheses.

CONCLUSION

Hip aspiration is an accurate and cost-effective method of evaluating the potentially infected hip prosthesis.

摘要

目的

评估荧光透视引导下髋关节穿刺抽吸术在诊断髋关节假体感染中的准确性。

材料与方法

将147例术前穿刺抽吸培养结果与手术培养结果进行比较。同时比较了穿刺抽吸术与核医学检查的相对成本。

结果

以手术培养结果为标准,髋关节穿刺抽吸术的敏感性为92.8%,特异性为91.7%。阴性预测值和阳性预测值分别为99.2%和54.2%。穿刺关节造影的成本约为用于评估潜在感染髋关节假体的最准确的核医学检查——锝硫胶体 - 铟 - 111粒细胞扫描的20%。

结论

髋关节穿刺抽吸术是评估潜在感染髋关节假体的一种准确且具有成本效益的方法。