Graziano G, Jaggers C, Lee M, Lynch W
Orthopaedic Research Laboratories, University of Michigan, Ann Arbor.
Spine (Phila Pa 1976). 1993 Dec;18(16):2383-7. doi: 10.1097/00007632-199312000-00003.
Primary screw fixation of a Type II odontoid fracture or non-union is an attractive alternative to posterior atlanto-axial arthrodesis in that normal cervical motion can be maintained. Eight cervical cadaver spines, ranging in age from 17-90 years, were used for study. Type II fractures of the dens were created using an osteotome. Simulated fractures were fixed using one or two 3.5-mm bone screws. After testing each screw fixation technique, the screws were removed and a posterior C1-C2 brooks sublaminar wiring was performed using four 18-gauge wires with wooden blocks to simulate bone graft. No significant differences were found between bending and torsional stiffnesses for the one-screw and two-screw specimens. No significant differences were found between one- and two-screw fixation when compared with primary C1-C2 wiring in torsion. One- or two-screw fixation was as stiff as primary C1-C2 wiring in bending. One or two screws offers similar stability for fixation for a dens fracture. One- and two-screw fixation is at least as stiff as primary C1-C2 wiring in torsion and one- or two-screw fixation is stiffer than primary C1-C2 wiring in bending.
II型齿状突骨折或不愈合的一期螺钉固定是后路寰枢关节融合术的一种有吸引力的替代方法,因为可以维持正常的颈椎活动。使用了8个年龄在17至90岁之间的颈椎尸体脊柱进行研究。使用骨刀制造齿状突的II型骨折。模拟骨折用一枚或两枚3.5毫米骨螺钉固定。在测试每种螺钉固定技术后,取出螺钉,并用四根18号钢丝和木块进行后路C1-C2布鲁克斯椎板下钢丝固定,以模拟植骨。单螺钉和双螺钉标本在弯曲和扭转刚度方面未发现显著差异。与一期C1-C2钢丝固定相比,单螺钉和双螺钉固定在扭转方面未发现显著差异。单螺钉或双螺钉固定在弯曲时与一期C1-C2钢丝固定一样坚固。一枚或两枚螺钉对齿状突骨折的固定提供了相似的稳定性。单螺钉和双螺钉固定在扭转时至少与一期C1-C2钢丝固定一样坚固,且单螺钉或双螺钉固定在弯曲时比一期C1-C2钢丝固定更坚固。