Suppr超能文献

Continuous intrauterine copper contraception for 3 years: comparison of replacement at 2 years with continuation of use.

作者信息

Newton J, Illingworth R, Elias J, McEwan J

出版信息

Br Med J. 1977 Jan 22;1(6055):197-9. doi: 10.1136/bmj.1.6055.197.

Abstract

A total of 1245 women had a copper 7 intrauterine contraceptive device (IUD) inserted in 1971-3 were followed up for three years (22 761-5 women months of use). After 24 months 483 women elected to continue with the same copper 7 (continuation group), and 183 had their copper 7 replaced with a new one (replacement group). The subsequent pregnancy and expulsion rates were both significantly lower in the replacement group. The higher pregnancy rate among the women who continued to use their copper 7 device for a third year suggests that although the copper is still there, it is not available for contraceptive action. Replacing the device at 24 months did not seem to cause again the problems that usually occur in the first six months of IUD use.

摘要

相似文献

2
Immediate postpartum intrauterine device and implant program outcomes: a prospective analysis.
Am J Obstet Gynecol. 2017 Jul;217(1):51.e1-51.e7. doi: 10.1016/j.ajog.2017.03.015. Epub 2017 Mar 23.
5
Continuation of copper and levonorgestrel intrauterine devices: a retrospective cohort study.
Am J Obstet Gynecol. 2017 Jul;217(1):57.e1-57.e6. doi: 10.1016/j.ajog.2017.03.005. Epub 2017 Mar 16.
7
Six-month and 1-year continuation rates following postpartum insertion of implants and intrauterine devices.
Contraception. 2015 Dec;92(6):532-5. doi: 10.1016/j.contraception.2015.09.007. Epub 2015 Sep 25.
9
Comparison of copper intrauterine device with levonorgestrel-bearing intrauterine system for post-abortion contraception.
J Obstet Gynaecol Res. 2015 Sep;41(9):1426-32. doi: 10.1111/jog.12747. Epub 2015 Jul 14.

引用本文的文献

1
Statistics and ethics in medical research. VII--Interpreting results.
Br Med J. 1980 Dec 13;281(6255):1612-4. doi: 10.1136/bmj.281.6255.1612.
3
Release of copper from intrauterine contraceptive devices.
Br Med J. 1977 Oct 22;2(6094):1087. doi: 10.1136/bmj.2.6094.1087.
4
Release of copper from copper-bearing intrauterine contraceptive devices.
Br Med J. 1977 Jul 30;2(6082):288-91. doi: 10.1136/bmj.2.6082.288.
5
Intrauterine deposition of calcium on copper-bearing intrauterine contraceptive devices.
Br Med J. 1977 Jan 22;1(6055):202-6. doi: 10.1136/bmj.1.6055.202.

本文引用的文献

2
Intrauterine contraception with the copper 7: evaluation after two years.
Br Med J. 1974 Aug 17;3(5928):447-50. doi: 10.1136/bmj.3.5928.447.
3
Intrauterine contraception using the copper-seven device.
Lancet. 1972 Nov 4;2(7784):951-4. doi: 10.1016/s0140-6736(72)92475-0.
4
The Copper T 220C: a new long-acting copper intrauterine contraceptive device.
Am J Obstet Gynecol. 1976 Jan 15;124(2):121-4. doi: 10.1016/s0002-9378(16)33285-9.
5
Four years experience with the Cu7 200 device-endouterine copper in fertility control.
Contraception. 1976 Jan;13(1):7-15. doi: 10.1016/0010-7824(76)90070-6.
6
Calcareous deposits formed on IUDs in human exposures.
Contraception. 1976 Nov;14(5):507-17. doi: 10.1016/0010-7824(76)90002-0.
7
Intrauterine deposition of calcium on copper-bearing intrauterine contraceptive devices.
Br Med J. 1977 Jan 22;1(6055):202-6. doi: 10.1136/bmj.1.6055.202.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验