Acquisition and measurement of left ventricular (LV) volumes with a three-dimensional data set of cine magnetic resonance (MR) images from apex to base is a time-consuming process. Results of a study with 10 healthy volunteers and 10 patients with LV hypertrophy were prospectively evaluated. The heart was shown in the anatomic short- and horizontal long-axis planes with cine MR imaging. LV volumes were measured with various geometric models, and ejection fractions were calculated. In both groups, the values of LV stroke volume obtained with a modified Simpson rule and biplane ellipsoid models correlated well to the analysis of the three-dimensional data set of cine MR images. There were no significant differences for the calculated ejection fraction between values obtained with the modified Simpson rule or the biplane ellipsoid model versus the three-dimensional data set. A high inter-observer reproducibility of cine MR measurements with the two former models was found. Therefore, modified Simpson rule and biplane ellipsoid models, with their shorter acquisition and processing times, may increase the clinical utility of cine MR imaging.
利用从心尖到心底的电影磁共振(MR)图像三维数据集获取和测量左心室(LV)容积是一个耗时的过程。对10名健康志愿者和10名左心室肥厚患者的研究结果进行了前瞻性评估。通过电影MR成像在解剖短轴和水平长轴平面显示心脏。用各种几何模型测量LV容积,并计算射血分数。在两组中,用改良Simpson法则和双平面椭圆体模型获得的LV每搏输出量值与电影MR图像三维数据集的分析结果相关性良好。改良Simpson法则或双平面椭圆体模型获得的值与三维数据集之间计算的射血分数无显著差异。发现前两种模型的电影MR测量具有较高的观察者间可重复性。因此,改良Simpson法则和双平面椭圆体模型,因其采集和处理时间较短,可能会增加电影MR成像的临床实用性。