Arentsen J J, Rodriques M M, Laibson P R
Invest Ophthalmol Vis Sci. 1977 Jan;16(1):32-8.
Six patients had penetrating keratoplasty following thermokeratoplasty (TKP) at different time intervals. The standard temperature used was between 90 degree and 95 degree C. with constant saline irrigation. The corneal buttons were studied by light and electron microscopy. Immediate changes observed included epithelial necrosis, marked degneration of keratocytes, and endothelial edema. After 24 hours, evidence of acute inflammation was noted in the subeptihelial zone and superficial stroma, and the endothelial changes persisted. One month after TKP, there was evidence of cellular regeneration of all the corneal layers. Eight months later, regeneration of the endothelial cells, keratocytes, and epithelium was present. Regeneration of the epithelial basement membrane was defective.
6例患者在不同时间间隔接受热角膜成形术(TKP)后进行了穿透性角膜移植术。使用的标准温度在90摄氏度至95摄氏度之间,并持续进行盐水冲洗。对角膜植片进行了光镜和电镜研究。观察到的即刻变化包括上皮坏死、角膜细胞明显退变和内皮水肿。24小时后,在角膜上皮下区域和浅层基质中发现急性炎症迹象,内皮变化持续存在。TKP术后1个月,所有角膜层均有细胞再生迹象。8个月后,内皮细胞、角膜细胞和上皮均有再生。上皮基底膜的再生存在缺陷。