Roy R B, Buccafuri A, Salpeter J
J Assoc Off Anal Chem. 1977 Jan;60(1):122-5.
A simple, rapid, and reproducible semiautomated method is described for routine analysis of riboflavin in premixes containing high levels of reduced iron. Reduced iron is separated from premixes by a magnet before digestion with sulfuric acid solution. The presence of ferrous sulfate, ferric pyrophosphate, and sodium ferric pyrophosphate in premixes did not affect the analytical results for riboflavin. Pretreating sample extracts with potassium permanganate and hydrogen peroxide gave variable results for riboflavin. Possible causes and mechanisms of iron interferences in fluorometric riboflavin analysis are briefly discussed. The procedure developed is capable of analyzing 40 samples/hr.
本文描述了一种简单、快速且可重复的半自动化方法,用于常规分析含铁量高的预混料中的核黄素。在用硫酸溶液消化之前,用磁铁将预混料中的还原铁分离出来。预混料中硫酸亚铁、焦磷酸铁和焦磷酸铁钠的存在不影响核黄素的分析结果。用高锰酸钾和过氧化氢预处理样品提取物,核黄素的结果不一。简要讨论了荧光法分析核黄素时铁干扰的可能原因和机制。所开发的方法能够每小时分析40个样品。