[Standardization in hematology and the use of the data in clinical laboratories].

作者信息

Tatsumi N, Tsuda I, Kondoh H

机构信息

Department of Clinical and Laboratory Medicine, Osaka City University Medical School.

出版信息

Rinsho Byori. 1993 May;41(5):592-5.

PMID:8350530
Abstract

Recently developed automated blood cell counters provide accurate and precise data on complete blood count (CBC). The results of nationwide surveys obtained using them are usually better than those obtained by biochemical tests. The precision of CBC counting has been improved owing to the efforts of laboratories and manufacturers. As for hemoglobinometry, the cyanmethemoglobin and oxyhemoglobin methods used in blood cell counters gave different results for fresh and artificial blood in control surveys. Now instead of the oxyhemoglobin method, the sodium lauryl sulfate-hemoglobin method is used to minimize the variation among different counters. The biggest problem at present is the lack of control blood which can be used for any blood cell counter. Another problem is the laboratory report sent to clinicians, which gives only numerical data. However, other comments and normal reference values should also be presented. Sufficient care may not be taken for normal reference values; they vary considerably among different laboratories. Also, most laboratories and manufacturers now use various conventional units for CBC, but the SI unit should be used for comparison of the data. In conclusion, nationwide unification of CBC values should be established in the near future with cooperative efforts by laboratories and manufacturers.

摘要

相似文献

1
[Standardization in hematology and the use of the data in clinical laboratories].
Rinsho Byori. 1993 May;41(5):592-5.
2
[Standardization Committee for Haematology. External Quality Assurance Program for General Hematology. Evaluation of the 1994 results].[血液学标准化委员会。普通血液学外部质量保证计划。1994年结果评估]
Sangre (Barc). 1996 Apr;41(2):115-23.
3
Hematology laboratory standardization: a plan for harmonization in Asia.
Southeast Asian J Trop Med Public Health. 1999;30 Suppl 3:182-4.
4
Evaluation of the Beckman Coulter AcT 5 diff AL hematology analyzer in a hospital setting.贝克曼库尔特AcT 5 diff AL血液分析仪在医院环境中的评估
Lab Hematol. 2003;9(3):167-74.
5
[Accuracy, precision and clinically acceptable level of complete blood cell count by an automated multichannel hematology analyzer].[全自动多通道血液学分析仪检测全血细胞计数的准确性、精密度及临床可接受水平]
Rinsho Byori. 1999 Apr;47(4):343-52.
6
Evaluation of hematological values obtained with reference automated hematology analyzers of six manufacturers.对六个制造商的参考自动血液分析仪所获得的血液学值进行评估。
Southeast Asian J Trop Med Public Health. 2002;33 Suppl 2:62-7.
7
EQAS for peripheral blood morphology in Spain: a 6-year experience.西班牙外周血形态学的外部质量评估服务:六年经验
Int J Lab Hematol. 2008 Dec;30(6):460-6. doi: 10.1111/j.1751-553X.2007.00975.x.
8
External quality assessment of automated hematology analyzer performance using fresh human blood samples in Shanghai.上海地区使用新鲜人血样本对自动血液分析仪性能进行的外部质量评估。
Lab Hematol. 2003;9(3):175-8.
9
The international consensus group for hematology review: suggested criteria for action following automated CBC and WBC differential analysis.国际血液学审查共识小组:自动全血细胞计数和白细胞分类分析后的行动建议标准。
Lab Hematol. 2005;11(2):83-90. doi: 10.1532/LH96.05019.
10
Plan and process for hematology laboratory standard in Thailand.泰国血液学实验室标准的规划与流程
Southeast Asian J Trop Med Public Health. 1999;30 Suppl 3:173-6.